Objective: Aortic valve disease is the most common acquired valvular heart disease in adults. With the increasing elderly population, the proportion of patients with symptomatic aortic stenosis who are unsuitable for conventional surgery is increasing. Transcatheter aortic valve implantation has rapidly gained credibility as a valuable alternative to surgery to treat these patients; however, they often have severe iliac-femoral arteriopathy, which renders the transfemoral approach unusable. We report our experience with the trans-subclavian approach for transcatheter aortic valve implantation using the CoreValve (Medtronic CV Luxembourg S.a.r.l.) in 6 patients.
Methods: In May 2008 to September 2009, 6 patients (mean age of 82 ± 5 years), with symptomatic aortic stenosis and no reasonable surgical option because of excessive risk, were excluded from percutaneous femoral CoreValve implantation because of iliac-femoral arteriopathy. These patients underwent transcatheter aortic valve implantation via the axillary artery. Procedures were performed by a combined team of cardiologists, cardiac surgeons, and anesthetists in the catheterization laboratory. The CoreValve 18F delivery system was introduced via the left subclavian artery in 6 patients, 1 with a patent left internal thoracic to left anterior descending artery graft.
Results: Procedural success was obtained in all patients, and the mean aortic gradient decreased 5 mm Hg or less immediately after valve deployment. One patient required implantation of a permanent pacemaker. One patient required a subclavian covered stent implantation to treat a postimplant artery dissection associated with difficult surgical hemostasis. One patient was discharged in good condition but died of pneumonia 40 days after the procedure. All patients were asymptomatic on discharge, with good mid-term prosthesis performance.
Conclusions: Transcatheter aortic valve implantation via a surgical subclavian approach seems safe and feasible, offering a new option to treat select, inoperable, and high-risk patients with severe aortic stenosis and peripheral vasculopathy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jtcvs.2010.01.027 | DOI Listing |
Sci Rep
January 2025
Deutsches Herzzentrum der Charité, Department of Congenital and Pediatric Heart Surgery, Augustenburger Platz 1, 13353, Berlin, Germany.
Limited magnetic resonance imaging (MRI) data on autograft dilatation following the Ross procedure in congenital cohorts presents challenges in understanding its evolution and impact on clinical outcomes. This study, spanning from February 2003 to December 2022, included patients under 40 years at the time of the Ross procedure, with MRI follow-ups assessing dimensions at key aortic sites. Among 307 patients, 132 MRIs were analyzed from 76 individuals, revealing that autograft z-scores increase primarily with time post-procedure (Coef.
View Article and Find Full Text PDFOpen Heart
January 2025
Department of Cardiothoracic and Vascular Surgery, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Aims: Exercise testing remains underused in patients with aortic stenosis (AS), partly due to concerns about an exercise-induced drop in systolic blood pressure (SBP). We aimed to study the SBP response to exercise in patients with severe symptomatic AS prior to surgery and 1 year postoperatively.
Methods: Patients scheduled for aortic valve replacement due to severe symptomatic AS were enrolled at a single centre in a prospective observational cohort study.
Open Heart
January 2025
Massachusetts General Hospital, Boston, Massachusetts, USA.
Background: Accurate mortality prediction following transcatheter aortic valve implantation (TAVI) is essential for mitigating risk, shared decision-making and periprocedural planning. Surgical risk models have demonstrated modest discriminative value for patients undergoing TAVI and are typically poorly calibrated, with incremental improvements seen in TAVI-specific models. Machine learning (ML) models offer an alternative risk stratification that may offer improved predictive accuracy.
View Article and Find Full Text PDFEBioMedicine
January 2025
CONNECT-AI Research Center, Yonsei University College of Medicine, Seoul, Republic of Korea; Ontact Health Inc., Seoul, Republic of Korea; Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Yonsei University Health System, Seoul, Republic of Korea.
Background: Transthoracic echocardiography (TTE) is the primary modality for diagnosing aortic stenosis (AS), yet it requires skilled operators and can be resource-intensive. We developed and validated an artificial intelligence (AI)-based system for evaluating AS that is effective in both resource-limited and advanced settings.
Methods: We created a dual-pathway AI system for AS evaluation using a nationwide echocardiographic dataset (developmental dataset, n = 8427): 1) a deep learning (DL)-based AS continuum assessment algorithm using limited 2D TTE videos, and 2) automating conventional AS evaluation.
J Investig Med High Impact Case Rep
January 2025
The University of the West Indies, St. Augustine, Trinidad and Tobago.
We describe a 30-year-old Caribbean-Black woman with a clinical presentation suggestive of a transient ischemic attack (TIA) with no conventional cerebrovascular risk factors, albeit with a newly diagnosed quadricuspid aortic valve (QAV) with moderate aortic regurgitation (AR). Although QAV is a recognized congenital cardiac defect, its association with TIA remains elusive. This case highlights the importance of considering potential atypical etiologies, such as QAV, in the evaluation and management of young patients presenting with cerebrovascular events.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!