A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

MicroNester coils as an adjunct to endovascular embolization. | LitMetric

MicroNester coils as an adjunct to endovascular embolization.

World Neurosurg

Department of Neurosurgery, Mayo Clinic, Rochester, Minnesota, USA.

Published: April 2010

Objectives/background: In June 2003, detachable balloons were removed from the US market and were supplanted with coil embolization for parent artery sacrifice in difficult or nonsurgical aneurysms and other vascular pathologies. The current series examines the use of MicroNester pushable coils (Cook Medical, Bloomington, IN) as a low-cost and effective adjunct to detachable coils in the treatment of selected neurovascular pathologies.

Methods: A retrospective analysis of all patients undergoing neurointerventional procedures from November 2003 through May 2008 was performed to identify patients in whom MicroNester coils were used as part of treatment. Analysis of coil type and number as well as pathology was performed.

Results: MicroNesters were used in 26 cases, of which 21 were for arterial sacrifice--19 for the internal carotid artery and 2 for the vertebral artery. Fourteen were performed for intracranial aneurysms, 3 for pseudoaneurysms, 2 for carotid cavernous fistulae, 1 for a carotid blowout, and 1 for an arteriovenous malformation. Five additional procedures were transvenous, for treatment of dural arterial venous fistulae. The mean number of coils for artery sacrifice was 13, with an average of 10 MicroNesters. For transvenous embolizations, the means were 30 and 6, respectively.

Conclusion: MicroNesters are not the coil of choice for most neurointerventional procedures because they are not retrievable. However, when parent artery sacrifice or transvenous occlusion of dural arteriovenous fistulas is the goal, MicroNesters are a relatively inexpensive and equally effective alternative to more expensive, detachable coils and can reduce the procedural costs by $3600 to $6000 for the current series.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2010.01.014DOI Listing

Publication Analysis

Top Keywords

artery sacrifice
12
micronester coils
8
parent artery
8
current series
8
detachable coils
8
coils treatment
8
neurointerventional procedures
8
artery
5
coils
5
coils adjunct
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!