A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Efficacy of hydrogastric sonography and spiral Computed Tomography in staging of gastric carcinoma--a comparative study. | LitMetric

Objective: Accurate preoperative diagnosis and staging of patients with gastric cancer is essential for optimal treatment. The standard of care for staging gastric carcinoma is helical CT. This study was conducted to compare the efficacy of hydrogastric sonography (HGS) with that of helical CT in the staging of patients with gastric carcinoma.

Methods: A total of 42 consecutive patients (29 men and 13 women) diagnosed with gastric carcinoma after endoscopy and biopsy were staged on the basis of TNM classification, preoperatively with HGS and helical CT and postoperatively with histopathologic examination (HPE). The findings of HGS and helical CT were compared with those on HPE with respect to TNM stage.

Results: Regarding T stage, the accuracy of HGS was 78.6% (kappa = 0.68) and that of helical CT was 66.7% (kappa = 0.48). In evaluating the nodal status, the accuracy of HGS was 66.7% (kappa = 0.52) and that of helical CT was 54.6% (kappa = 0.39). Regarding distant metastases, accuracy was the same with HGS and helical CT (accuracy 95.2%, kappa = 0.89).

Conclusions: When compared with HPE, HGS was found to be more accurate than helical CT for assessment of T and N staging. Sonographic and helical CT were equally accurate for the assessment of M stage.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jcu.20734DOI Listing

Publication Analysis

Top Keywords

hgs helical
16
accuracy hgs
12
helical
9
efficacy hydrogastric
8
hydrogastric sonography
8
staging gastric
8
staging patients
8
patients gastric
8
gastric carcinoma
8
compared hpe
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!