Background And Aim Of The Study: The most effective method for decellularization of the intact porcine aortic root remains controversial. Additionally, the hydrodynamic effect that such treatment may have on aortic roots has never been previously investigated. The study aim was to compare the in-vitro hydrodynamic performances of intact porcine aortic roots, both before and after decellularization treatment.
Methods: Fifteen fresh porcine aortic roots were tested in the aortic chamber of the Sheffield pulse duplicator (SPD). For study purposes, the roots were first sutured to a silicone aortic root and then hydrodynamically tested. After in-vitro testing, the fresh porcine aortic roots, while still fixed within the silicone root, were decellularized according to various protocols (TRI-COL, TRI-DOC, sodium dodecyl sulfate (SDS) 0.03%, and SDS 0.1%). After decellularization, the valve roots were re-tested, adopting identical testing conditions. Forward flow pressure drop, closing leakage volumes, effective orifice area (EOA), and stroke work loss were each monitored. Three roots, used as a control group, were tested in identical fashion before and after storage (without decellularization) for comparative purposes.
Results: The TRI-COL- and TRI-DOC-treated porcine aortic roots showed significantly lower transvalvular gradients, lower stroke work loss, lower valve resistance, and higher EOA than fresh intact porcine roots. In contrast, SDS 0.1%-treated porcine aortic roots showed opposing results, with the transvalvular gradients, stroke work loss and valve resistance each higher, and the EOA lower, than pre-treatment values. SDS 0.03% treatment had no significant effect on the hydrodynamic performance. After decellularization in all treatment groups, the diastolic parameters, total regurgitant volume and valve closing volume were each non-significantly increased. The aortic roots used as a control group showed similar results before and after storage.
Conclusion: Based on these results using the SPD, all treatments except for SDS 0.03% modified the systolic and diastolic functions of intact porcine aortic roots.
Download full-text PDF |
Source |
---|
Sci Rep
January 2025
Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden.
Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text].
View Article and Find Full Text PDFJ Thorac Cardiovasc Surg
December 2024
Department of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea. Electronic address:
Cardiovasc Ther
January 2025
Institute of Cardiovascular Science, Translational Medicine Institute, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi 710061, China.
Cysteinyl leukotrienes (LTs) and their receptors are involved in the pathogenesis of abdominal aortic aneurysms (AAAs). However, whether CysLT1 receptor antagonists such as montelukast can influence experimental nondissecting AAA remains unclear. Nondissecting AAAs were induced in C57BL/6J mice by transient aortic luminal infusion of porcine pancreatic elastase (PPE).
View Article and Find Full Text PDFSci Rep
December 2024
Department of Emergency and Critical Care Medicine, Jichi Medical University, Shimotsuke City, Tochigi, Japan.
Hemorrhagic shock is a significant cause of trauma-related mortality. Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a less-invasive aortic occlusion maneuver for severe hemorrhagic shock but potentially inducing oxidative stress injuries. In an animal model, this study investigated hydrogen gas inhalation therapy's potential to mitigate post-REBOA ischemia-reperfusion injuries (IRIs).
View Article and Find Full Text PDFSurg Endosc
December 2024
Cedars-Sinai Medical Center, Los Angeles, CA, USA.
Introduction: The inability to sense force applied to tissue is suggested as a limitation to robotic-assisted surgery (RAS). This pre-clinical study evaluated the impact of a novel force feedback (FFB) technology, integrated on a next-generation robotic system that allows surgeons to sense forces exerted at the instrument tips, on suturing performance by novice surgeons during RAS.
Methods: Twenty-nine novice surgeons (< 50 RAS cases in the last 5 years) were randomized into two groups with (n = 15) or without (n = 14) FFB sensing.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!