A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Utility of NucleoCounter for the chondrocyte count in the collagenase digest of human native cartilage. | LitMetric

Utility of NucleoCounter for the chondrocyte count in the collagenase digest of human native cartilage.

Cytotechnology

Department of Cartilage and Bone Regeneration (Fujisoft), Graduate Shool of Medicine, The University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo, 113-8655, Japan.

Published: December 2010

In cartilage tissue engineering, viable cell numbers should be correctly counted in the collagenase digest of the biopsied cartilage. However, this is a difficult task due to the presence of matrix debris, cell ghosts and their aggregates. To search for the correct cell counting method in this situation, we evaluated the utility of an automatic cell counting device, the NucleoCounter, and compared it with conventional staining using the LIVE/DEAD® kit. We first measured the cell numbers of a standard chondrocyte sample by the NucleoCounter, which showed a high accuracy (R(2) = 0.9999) and reproducibility (%CV: 2.00-8.66). We then calculated the cell numbers and viability in some collagenase digests of native cartilage using either the NucleoCounter or LIVE/DEAD® kit, revealing that the total cell numbers, viable ones and viability were highly correlated between them (R(2) = 0.9601, 0.9638 and 0.917, respectively). However, both the intrapersonal and interpersonal variabilities in the NucleoCounter was significantly decreased to about 1/20-1/5, compared to that of the LIVE/DEAD® kit. The NucleoCounter was regarded as a useful tool for simple, rapid, and highly reproducible cell counts, which may not only provide constant experimental data in a certain laboratory, but also contribute to the high reproducibility of the clinical results of cartilage tissue engineering among multiple institutions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2995145PMC
http://dx.doi.org/10.1007/s10616-010-9304-yDOI Listing

Publication Analysis

Top Keywords

cell numbers
16
live/dead® kit
12
collagenase digest
8
native cartilage
8
cartilage tissue
8
tissue engineering
8
cell
8
cell counting
8
cartilage
5
nucleocounter
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!