A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative analysis of four methods to extract DNA from paraffin-embedded tissues: effect on downstream molecular applications. | LitMetric

Background: A large portion of tissues stored worldwide for diagnostic purposes is formalin-fixed and paraffin-embedded (FFPE). These FFPE-archived tissues are an extremely valuable source for retrospective (genetic) studies. These include mutation screening in cancer-critical genes as well as pathogen detection. In this study we evaluated the impact of several widely used DNA extraction methods on the quality of molecular diagnostics on FFPE tissues.

Findings: We compared 4 DNA extraction methods from 4 identically processed FFPE mammary-, prostate-, colon- and lung tissues with regard to PCR inhibition, real time SNP detection and amplifiable fragment size. The extraction methods, with and without proteinase K pre-treatment, tested were: 1) heat-treatment, 2) QIAamp DNA-blood-mini-kit, 3) EasyMAG NucliSens and 4) Gentra Capture-Column-kit.Amplifiable DNA fragment size was assessed by multiplexed 200-400-600 bp PCR and appeared highly influenced by the extraction method used. Proteinase K pre-treatment was a prerequisite for proper purification of DNA from FFPE. Extractions with QIAamp, EasyMAG and heat-treatment were found suitable for amplification of fragments up to 400 bp from all tissues, 600 bp amplification was marginally successful (best was QIAamp). QIAamp and EasyMAG extracts were found suitable for downstream real time SNP detection. Gentra extraction was unsuitable. Hands-on time was lowest for heat-treatment, followed by EasyMAG.

Conclusions: We conclude that the extraction method plays an important role with regard to performance in downstream molecular applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2954845PMC
http://dx.doi.org/10.1186/1756-0500-3-239DOI Listing

Publication Analysis

Top Keywords

extraction methods
12
downstream molecular
8
molecular applications
8
dna extraction
8
real time
8
time snp
8
snp detection
8
fragment size
8
proteinase pre-treatment
8
extraction method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!