A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Smoke alarm and battery function 42 months after installation: a randomized trial. | LitMetric

Background: This randomized trial presents findings from the longest follow-up study of smoke alarm and battery function to date.

Purpose: The purpose of this study is to examine differences in long-term function of smoke alarm and battery combinations.

Methods: A total of 691 households in an ongoing cohort study were randomly allocated into smoke alarm groups of ionizing and photoelectric and battery groups of zinc and lithium. Smoke alarm function was measured in 633 (91.6%) households from January 2007 through February 2008, 42 months following original smoke alarm/battery installation. Data analyses were conducted in 2009.

Results: After 3.5 years, 81.9% of the 1898 smoke alarms were functional. Ionizing alarms with zinc batteries were the least likely to function (72.7%). In comparison, photoelectric alarms with lithium batteries were 2.9 times (95% CI=1.8, 4.5) more likely to function; ionizing alarms with lithium batteries were 2.0 times (95% CI=1.3, 3.1) more likely to function; and photoelectric alarms with zinc batteries were 1.7 times (95% CI=1.1, 2.5) more likely to function. Functionality was strongly tied to number of reports of nuisance alarms, which was higher for ionizing than photoelectric alarms.

Conclusions: Photoelectric smoke alarms and lithium batteries are the most likely to function long after smoke alarm installation, and may be worthwhile investments despite their increased cost.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amepre.2010.05.018DOI Listing

Publication Analysis

Top Keywords

smoke alarm
24
alarm battery
12
alarms lithium
12
lithium batteries
12
batteries times
12
times 95%
12
smoke
9
function
9
battery function
8
randomized trial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!