Purpose: The authors present results of the measurements on the impact of radiochromic film immersion in water. The impact of film piece size, initial optical density, postimmersion waiting time prior to scanning, and the time film was kept in water has been investigated. The authors also investigated the pathways of water penetration into the film during the film immersion in water.

Methods: To study the impact of water immersion on change in optical density, the authors used various sizes of the latest EBT-2 model GAFCHROMICTM film: 2 x 2, 4 x 4, and 8 x 8 in.2. In addition, to test any existing dependence of the film's optical density on water diffusion, the authors used two sets of films: Unexposed (0 Gy) and film pieces exposed to a dose of 3 Gy. Times that film pieces were left in water ranged from 30 min to 24 h, and once the film was permanently removed from water, the authors also studied the impact of the scanning time (deltat) that ranged from 0 (films scanned right after removal from water) to 72 h postimmersion.

Results: While the penetration depth can reach as much as 9 mm around the edges of the EBT-2 GAFCHROMIC film, the anticipated dose error due to the change in optical density due to the water immersion appears to be negligible for the short immersions of the order of 30 min. However, as the immersion time increases, the anticipated dose error may reach 22 cGy on a 2 x 2 in.2 piece of film, which corresponds to 7% dose error at 3 Gy of measured dose.

Conclusions: In this work, the authors report on an undoubted impact of radiochromic film immersion in water on the measured change in optical density, which may lead to systematic errors in dose measurements if the film is kept in water for longer periods of time. The magnitude of the impact depends on many parameters: Size of the film piece, initial optical density, postimmersion waiting time prior to scanning (defined by the current radiochromic film dosimetry protocol in. place), and the time film was kept in water. The authors also suggested various approaches in correcting for the change in netOD due to water penetration into the film, but the authors believe that the use of the control film piece would be the most appropriate.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.3455713DOI Listing

Publication Analysis

Top Keywords

optical density
24
film
19
water
14
radiochromic film
12
film immersion
12
film piece
12
film water
12
change optical
12
dose error
12
ebt-2 model
8

Similar Publications

Plasmonic materials can be utilized as effective platforms to enhance luminescent signals of luminescent metal nanoclusters (LMNCs). Both surface enhanced fluorescence (SEF) and shell-isolated nanoparticle-enhanced fluorescence (SHINEF) strategies take advantage of the localized and increased external electric field created around the plasmonic metal surface when excited at or near their characteristic plasmonic resonance. In this context, we present an experimental and computational study of different plasmonic composites, (Ag) Ag@SiO2 and (Au) Au@SiO2 nanoparticles, which were used to enhance the luminescent signal of Au nanoclusters coated with glutathione (GSH) molecule (Au25GSH NCs).

View Article and Find Full Text PDF

: This study aimed to assess the role of macular pigment optical density (MPOD) in patients with a full-thickness macular hole (FTMH) compared to healthy controls, evaluating postoperative changes in MPOD and exploring potential correlations with visual outcomes. : This prospective, cross-sectional, comparative study included 16 eyes from FTMH patients who achieved anatomical hole closure following pars plana vitrectomy with the inverted ILM flap technique. Each eye underwent a comprehensive ophthalmologic examination, including BCVA and intraocular pressure measurements, anterior segment evaluation, fundus examination, and macular assessment with Enhanced Depth Imaging Optical Coherence Tomography (EDI-OCT, Spectralis, Heidelberg Engineering Inc.

View Article and Find Full Text PDF

Diabetic macular edema (DME) is a significant cause of vision loss. The development of peripheral non-perfusion (PNP) might be associated with the natural course, severity, and treatment of DME. The present study seeks to understand the predictive power of central macular changes and clinico-demographic features for PNP in patients with clinically significant DME.

View Article and Find Full Text PDF

Understanding Cyclists' Visual Behavior Using Eye-Tracking Technology: A Systematic Review.

Sensors (Basel)

December 2024

Department of Civil Engineering and Architecture, University of Catania, 64 Santa Sofia Street, 95123 Catania, Italy.

Eye-tracking technologies are emerging in research aiming to understand the visual behavior of cyclists to improve their safety. These technologies gather real-time information to reveal what the cyclists look at and how they respond at a specific location and time. This systematic review investigates the use of eye-tracking systems to improve cyclist safety.

View Article and Find Full Text PDF

W/WO/TiO Multilayer Film with Elevated Electrochromic and Capacitive Properties.

Materials (Basel)

January 2025

College of Physics and Electronic Information, Shandong Key Laboratory of Biophysics, Dezhou University, Dezhou 253023, China.

Electrochromic capacitors, which are capable of altering their appearances in line with their charged states, are drawing substantial attention from both academia and industry. Tungsten oxide is usually used as an electrochromic layer material for electrochromic devices, or as an active material for high-performance capacitor electrodes. Despite this, acceptable visual aesthetics in electrochromic capacitors have almost never been achieved using tungsten oxide, because, in its pure form, this compound only displays a onefold color modulation from transparent to blue.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!