A tin-polyimide and an indium-polyimide soft x-ray bandpass filter were fabricated with thicknesses of 1400 and 1750 A for the metal and polyimide components, respectively. The transmission of each filter was measured at the Stanford Synchrotron Radiation Laboratory. The transmission of the tin-polyimide filter was found to be ~40% for radiation with wavelengths between 60 and 80 A. The transmission of the indium-polyimide filter was greater than 40% between 70 and 90 A. The indium was ~5% more transmissive than the tin and attained a maximum transmission of ~48% at 76 A. Such filters have potential applications to soft x-ray telescopes that operate in this region. They might also be of interest to investigators who work with x-ray microscopes that image live biological specimens in the 23-44-A water window.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.32.004855DOI Listing

Publication Analysis

Top Keywords

soft x-ray
12
tin-polyimide indium-polyimide
8
x-ray bandpass
8
indium-polyimide thin-film
4
thin-film composites
4
composites soft
4
x-ray
4
bandpass filters
4
filters tin-polyimide
4
indium-polyimide soft
4

Similar Publications

The distribution of substitutional aluminum (Al) atoms in zeolites affects molecular adsorbate geometry, catalytic activity, and shape and size selectivity. Accurately determining Al positions has been challenging. We used synchrotron resonant soft x-ray diffraction (RSXRD) at multiple energies near the Al K-edge combined with molecular adsorption techniques to precisely locate "single Al" and "Al pairs" in a commercial H-ZSM-5 zeolite.

View Article and Find Full Text PDF

Imaging Findings, Complications, and Mimics after Common and Advanced Dental Procedures.

Radiographics

February 2025

From the Department of Radiology, Nihon University School of Dentistry at Matsudo, 2-870-1 Sakaecho-Nishi, Matsudo, Chiba 271-8587, Japan (K.I., K.O., T.K.); Department of Diagnostic Radiology, National Cancer Center Hospital East, Chiba, Japan (H.K.); Department of Radiology, VA Boston Health Care System, Boston, Mass (V.C.A.A.); and Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.S.).

Various new dental treatment methods have been introduced in dental clinics, and many new materials have been used in recent years for dental treatments. Dentistry is divided into several specialties, each offering unique treatments, such as endodontics, implantology, oral surgery, and orthodontics. CT and MR images after dental treatment reveal a variety of hard- and soft-tissue changes and dental materials, which often cause image artifacts.

View Article and Find Full Text PDF

The bone marrow of immunocompromised patients may exhibit abnormalities due to the underlying disease, adverse treatment effects, and/or complications arising from either source. Such complexity poses a significant diagnostic challenge, particularly in children. Magnetic resonance imaging (MRI) is the modality of choice when evaluating bone marrow in these patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!