Background: Patient radiation exposure and consumption of contrast medium are considered major risks of diagnostic coronary angiography (CA). Rotation of the C-arm during CA could provide similar diagnostic accuracy and lower radiation exposure and contrast medium consumption.
Methods: To compare feasibility, safety, diagnostic accuracy, patient radiation exposure, and consumption of contrast medium of rotational CA with the invasive standard technique, intraindividual comparisons of the results obtained by both techniques were performed in 235 patients with an indication for first-time elective CA. In addition to conventional angiography, we performed 2 isocentric radiographic coronary spins with cranial and caudal tilts by 20 degrees around the left coronary artery and 1 strict posteroanterior rotational spin around the right coronary artery.
Results: In 16 patients, rotational CA was not performed because of safety concerns. In a further 12 patients, image quality of rotational scans was considered inadequate. In the remaining 207 patients, both modes of CA were proven suitable for anonymized, separate analysis by 3 independent cardiologists. Intraindividual comparison of both CA modes revealed a high degree of diagnostic agreement (Cohen (K) >0.8 for all cardiologists and for each coronary segment). Contrast medium volume during rotational CA and conventional CA amounted to 31.9 +/- 4.5 mL versus 52.2 +/- 8.0 mL (P < .001) and patient radiation exposure amounted to 5.0 +/- 2.6 Gy × cm(2) versus 11.5 +/- 5.5 Gy × cm(2) (P < .001), respectively.
Conclusions: Rotational CA represents a safe and feasible method in clinical routine. Whereas diagnostic accuracy is similar to the usual conventional mode, consumption of contrast medium and patient radiation exposure are significantly reduced.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ahj.2010.06.011 | DOI Listing |
PLoS One
January 2025
Department of ENT, Head and Neck Surgery, Sri Ramachandra Institute of Higher Education and Research (Deemed to be University), Chennai, Tamil Nadu, India.
Aim: The perspectives and practices of healthcare professionals regarding ototoxicity in individuals with head and neck cancers are important for the implementation of ototoxicity monitoring. The current study aims to explore the oncologist's awareness and perspectives of ototoxicity and ototoxicity monitoring for individuals with head and neck cancer in a South-Indian district, using qualitative semi-structured interviews.
Method: The COnsolidated criteria for REporting Qualitative research (COREQ) Checklist was used to guide the method of the current qualitative study.
PLoS One
January 2025
Department of Medicine Epidemiology and Population Sciences, Baylor College of Medicine, Houston, Texas, United States of America.
Objectives: It is significant to know how much early detection and screening could reduce the proportion of occult metastases and benefit NSCLC patients.
Methods: We used previously designed and validated mathematical models to obtain the characteristics of LC in the population including undetectable metastases at the time of diagnosis. The survival was simulated using the survival functions from Surveillance, Epidemiology and End Results (SEER) data stratified by stage.
Environ Geochem Health
January 2025
Nuclear Technology Research and Development Center, Thailand Institute of Nuclear Technology, Nakhon Nayok, 26120, Thailand.
The present study aimed to investigate the hydrogeochemical patterns and contamination of the radiogeology, especially radon activity, related to geothermal aquifer properties and to perform a risk assessment of annual effective doses covering all hydrothermal spring attractions in Southern Thailand. Radon is an established lung carcinogen; especially longer term exposure to radioactive radon through inhalation could be a cause of lung cancer risk. Altogether 22 hydrothermal spring samples were collected from the six hydrothermal provinces in Southern Thailand in early November of 2023.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
Alzheimer's Disease Neuroimaging Initiative, http://adni.loni.usc.edu/, CA, USA.
Background: Assessing tau accumulation in early affected areas like the lateral entorhinal cortex (EC) and inferior temporal gyrus (ITG) enables early prediction of disease progression and cognitive decline. However, positron emission tomography (PET) imaging poses radiation exposure and cost concerns. This research aims to develop a deep learning model predicting tau positivity in these regions using MRI.
View Article and Find Full Text PDFInt J Radiat Biol
January 2025
N.N. Semenov Federal Research Center for Chemical Physics, Russian Academy of Sciences, Moscow, Russia.
Background: Enumeration of residual DNA repair foci 24 hours or more after exposure to ionizing radiation (IR) is often used to assess the efficiency of DNA double-strand break repair. However, the relationship between the number of residual foci in irradiated cells and the radiation dose is still poorly understood. The aim of this work was to investigate the dose responses for residual DNA repair foci in normal human fibroblasts after X-ray exposure in the absorbed dose range from 0.