Background: Several studies have been published in the literature about intubation methods, but little is available on intubation equipment used in this setting. This is the first prehospital comparison of disposable plastic vs disposable stainless steel laryngoscope blades used by paramedics.

Study Objective: The objective of this study was to compare prehospital intubation success rates on first attempt and overall number of attempts to obtain intubations using disposable plastic laryngoscopes blades vs disposable stainless steel laryngoscope blades.

Methods: A retrospective prehospital cohort study was conducted during two 3-year periods. Two-way contingency table and χ(2) test were conducted to determine if there was a difference between the 2 types of blades. A proportional odds model with calculated 95% confidence interval (CI) and odd ratios were then calculated.

Results: A total of 2472 paramedic intubations were recorded over the 6-year period. The stainless steel single-use blades had a first attempt success rate of 88.9% vs 78.5% with plastic blades (P = .01; odds ratio, 1.94; 95% CI, 1.17-3.41). The stainless steel single-use laryngoscope blade had a lower number of attempts to successful intubation than the plastic blade (88.8% vs 74.3%, respectively) (P < .01; odds ratio, 1.64; 95% CI, 1.34-2.00).

Conclusions: In the prehospital setting, stainless steel disposable blades were superior to plastic disposable blades in first attempt and overall number of attempts to intubation. Until further research is done, we recommend use of stainless steel blades for intubations in the prehospital setting by paramedics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajem.2009.12.022DOI Listing

Publication Analysis

Top Keywords

stainless steel
28
disposable stainless
12
number attempts
12
blades
9
laryngoscope blades
8
disposable plastic
8
plastic disposable
8
steel laryngoscope
8
attempt number
8
steel single-use
8

Similar Publications

Magnetic nanoparticles of Nd2Fe14B prepared by ethanol-assisted wet ball milling technique.

Sci Rep

January 2025

Environmental and Occupational Hazards Control Research Center, Research Institute for Health Sciences and Environment, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

The magnetic material Nd2Fe14B is one of the strongest magnetic materials found in nature. The demand for the production of these nanoparticles is significantly high due to their exceptional properties. The aim of the present study is to synthesize magnetic nanoparticles of Nd2Fe14B using ethanol in the wet ball milling technique (WBMT).

View Article and Find Full Text PDF

Electrochemical pH modulator coupled with Ni-based electrode for glucose sensing.

Talanta

January 2025

Université de Lorraine, CNRS, Laboratoire de Chimie Physique et Microbiologie pour Les Matériaux et L'Environnement (LCPME), Nancy F-54000, France.

The non-enzymatic electrochemical detection of glucose by direct oxidation using electrodes modified with suitable electrocatalysts is now well-established. However, it most often requires highly alkaline media, limiting dramatically the use of such electrodes at neutral pH. This is notably the case of Ni-based electrodes.

View Article and Find Full Text PDF

Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic compounds resulting from incomplete burning of organic materials. This work describes the successful layer-by-layer fabrication of a novel zinc oxide nanocomposite made of zinc oxide nanoparticles, aniline, sodium dodecyl sulfate, and modified multi-walled carbon nanotubes on a stainless steel wire by electrodeposition. The coating and extraction conditions were screened, optimized, and validated using factorial design and central composite design, respectively.

View Article and Find Full Text PDF

Flexible Vibration Sensors with Omnidirectional Sensing Enabled by Femtosecond Laser-Assisted Fabrication.

Polymers (Basel)

January 2025

State Key Laboratory of Precision Manufacturing for Extreme Service Performance, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China.

Vibration sensors are integral to a multitude of engineering applications, yet the development of low-cost, easily assembled devices remains a formidable challenge. This study presents a highly sensitive flexible vibration sensor, based on the piezoresistive effect, tailored for the detection of high-dynamic-range vibrations and accelerations. The sensor's design incorporates a polylactic acid (PLA) housing with cavities and spherical recesses, a polydimethylsiloxane (PDMS) membrane, and electrodes that are positioned above.

View Article and Find Full Text PDF

Fischer-Tropsch synthesis (FTS) in a 3D-printed stainless steel (SS) microchannel microreactor was investigated using Fe@SiO catalysts. The catalysts were prepared by two different techniques: one pot (OP) and autoclave (AC). The mesoporous structure of the two catalysts, Fe@SiO (OP) and Fe@SiO (AC), ensured a large contact area between the reactants and the catalyst.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!