Aortic coarctation complicated by wall aneurysm: the role of covered stents.

Catheter Cardiovasc Interv

Pediatric Cardiology and GUCH Unit, Istituto Policlinico San Donato, IRCCS, San Donato Milanese, Italy.

Published: November 2011

Objectives: To evaluate the management of aneurysms associated with aortic coarctation by covered stent deployment.

Background: Aortic aneurysm formation complicating aortic coarctation carries a risk of rupture with high mortality rate. Surgical repair has a significant mortality and may be associated with central nervous system injury, including paraplegia. Transcatheter intervention alternatively carries a risk of aneurysmal rupture.

Methods: Between July 2004 and September 2009, 140 consecutive patients underwent percutaneous stent implantation to treat aortic coarctation. Eleven (7.9%) patients had coarctation associated with aortic wall aneurysm: three with native coarctation with wall aneurysm, three with previous surgical coarctation repair, three with previous balloon angioplasty, and two with previous bare stent implantation. The e-PTFE-covered 8Zig Cheatham-Platinum stents were used to treat all 11 patients.

Results: Median age at procedure was 13 years (range, 6-66 years). Successful device deployment was achieved in all patients. Systolic pressure gradient reduced significantly from a median baseline of 30 mm Hg (range, 25-50 mm Hg) to a postprocedural median of 5 mm Hg (range, 0-20 mm Hg) (P < 0.01). Aortic diameter increased from a median value of 6 mm (range, 0.5-11 mm) to a median value of 12 mm (range, 10-22 mm) (P < 0.001). No early complications occurred, with successful relief of stenoses and complete sealing of all aneurysms. Median follow-up was 50 months (range, 16-61 months). Redilatation was required in four patients (one patient with intrastent restenosis secondary to significant endothelial growth, whereas the other three patients showed restenosis secondary to somatic growth). Redilatation with a larger balloon was performed without complication in all cases.

Conclusions: Our data show that covered stents are a safe and effective treatment with low risk of complications for the treatment of coarctation associated with aortic wall aneurysm.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.22756DOI Listing

Publication Analysis

Top Keywords

aortic coarctation
16
wall aneurysm
16
associated aortic
12
median range
12
aortic
8
covered stents
8
carries risk
8
stent implantation
8
coarctation associated
8
aortic wall
8

Similar Publications

Desmoid tumors are a rare entity, especially in the pediatric population. There are no reports of such a tumor in newborns. They are associated with high rates of morbidity and mortality, even though they are benign soft tissue tumors.

View Article and Find Full Text PDF

Background: Aortic coarctation (CoA) is a congenital anomaly leading to upper-body hypertension and lower-body hypotension. Despite surgical or interventional treatment, arterial hypertension may develop and contribute to morbidity and mortality. Conventional blood pressure (BP) measurement methods lack precision for individual diagnoses and therapeutic decisions.

View Article and Find Full Text PDF

Prenatal Diagnosis of Berry Syndrome by Fetal Echocardiography.

Ultrasound Q

March 2025

Department of Echocardiography, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China.

Berry syndrome is a rare combination of cardiac malformations, which is characterized by the following malformations, including the aortopulmonary window, aortic right pulmonary origin, interrupted aortic arch or hypoplastic aortic arch or coarctation of the aorta, and an intact ventricular septum. There are few reviews on prenatal diagnosis of Berry syndrome by fetal echocardiography. We used sequential cross-sectional scanning from apex to bottom of the heart to find aortic right pulmonary origin, aortopulmonary window, and hypoplastic aortic arch.

View Article and Find Full Text PDF

This study examines how heart rate (HR) affects hemodynamics in a South African infant with Coarctation of the Aorta. Computed tomography angiography segments aortic coarctation anatomy; Doppler echocardiography derives inlet flow waveforms. Simulations occur at 100, 120, and 160 beats per minute, representing reduced, resting, and elevated HR levels.

View Article and Find Full Text PDF

Background: Recurrent coarctation of the aorta (re-CoA) is a well-known although not fully understood complication after surgical repair, typically occurring in 10%-20% of cases within months after discharge.

Objectives: To (1) characterize geometry of the aortic arch and blood flow from pre-discharge magnetic resonance imaging (MRI) in neonates after CoA repair; and (2) compare these measures between patients that developed re-CoA within 12 months after repair and patients who did not.

Methods: Neonates needing CoA repair, without associated major congenital heart defects, were included.

View Article and Find Full Text PDF