Dosimetric characteristics of a metal oxide-silicon semiconductor field effect transistor (MOSFET) detector are studied with megavoltage photon beams for patient dose verification. The major advantages of this detector are its size, which makes it a point dosimeter, and its ease of use. In order to use the MOSFET detector for dose verification of intensity-modulated radiation therapy (IMRT) and in-vivo dosimetry for radiation therapy, we need to evaluate the dosimetric properties of the MOSFET detector. Therefore, we investigated the reproducibility, dose-rate effect, accumulated-dose effect, angular dependence, and accuracy in tissue-maximum ratio measurements. Then, as it takes about 20 min in actual IMRT for the patient, we evaluated fading effect of MOSFET response. When the MOSFETs were read-out 20 min after irradiation, we observed a fading effect of 0.9% with 0.9% standard error of the mean. Further, we applied the MOSFET to the measurement of small field total scatter factor. The MOSFET for dose measurements of small field sizes was better than the reference pinpoint chamber with vertical direction. In conclusion, we assessed the accuracy, reliability, and usefulness of the MOSFET detector in clinical applications such as pinpoint absolute dosimetry for small fields.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12194-007-0007-9 | DOI Listing |
Asian Pac J Cancer Prev
May 2024
Department of Radiotherapy, SP Medical college, Bikaner, Rajasthan, India.
Aim: To evaluate the out-of-field dose associated with flattened (FF) and flattening filter-free (FFF) 6 and 10 MV X-ray beams in a TrueBeam linear accelerator (Linac).
Materials And Methods: Measurements were taken in a slab phantom using the metal oxide semiconductor field effect transistor (MOSFET) detector at varying depths (dmax, 5 cm, and 10 cm) for clinically relevant field sizes and up to 30 cm from the field edges for 6 and 10 MV FF and FFF beams in TrueBeam Linac. Dose calculation accuracy of the analytic anisotropic algorithm (AAA) and Acuros algorithm was investigated in the out-of-field region.
Sensors (Basel)
June 2023
State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 500 Yu Tian Road, Shanghai 200083, China.
Studying the nonlinear photoresponse of different materials, including III-V semiconductors, two-dimensional materials and many others, is attracting burgeoning interest in the terahertz (THz) field. Especially, developing field-effect transistor (FET)-based THz detectors with preferred nonlinear plasma-wave mechanisms in terms of high sensitivity, compactness and low cost is a high priority for advancing performance imaging or communication systems in daily life. However, as THz detectors continue to shrink in size, the impact of the hot-electron effect on device performance is impossible to ignore, and the physical process of THz conversion remains elusive.
View Article and Find Full Text PDFPhys Eng Sci Med
June 2023
Townsville Cancer Centre, Townsville Hospital and Health Service, Townsville, QLD, Australia.
The magnetic field of a transverse MR-linac alters electron trajectories as the photon beam transits through materials, causing lower doses at flat entry surfaces and increased doses at flat beam-exiting surfaces. This study investigated the response of a MOSFET detector, known as the MOSkin™, for high-resolution surface and near-surface percentage depth dose measurements on an Elekta Unity. Simulations with Geant4 and the Monaco treatment planning system (TPS), and EBT-3 film measurements, were also performed for comparison.
View Article and Find Full Text PDFMaterials (Basel)
February 2023
Physics Department, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13318, Saudi Arabia.
Herein, we investigated the applicability of thick film and bulk disk forms of aluminum-doped zinc oxide (AZO) for low-dose X-ray radiation dosimetry using the extended gate field effect transistor (EGFET) configuration. The samples were fabricated using the chemical bath deposition (CBD) technique. A thick film of AZO was deposited on a glass substrate, while the bulk disk form was prepared by pressing the collected powders.
View Article and Find Full Text PDFAppl Radiat Isot
June 2023
University of Saarland, Clinic of Radiooncology, Homburg, 66421, Germany.
In this study, the authors examine the responses of radiation-sensitive p-channel MOSFETs to irradiation and subsequent annealing at room temperature and higher temperatures to investigate their use as a dosimeter for measuring ionizing radiation. The response of these transistors to radiation was monitored based on the shift in the threshold voltage as a function of the absorbed dose of radiation. The results showed that the shift in the threshold voltage depended on the densities of traps formed during exposure to ionizing radiation in Si and at the Si-SiO interface on which the charges were captured.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!