A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative study of 4Fr catheters using the ACIST variable rate injector system versus 6Fr catheters using hand manifold in diagnostic coronary angiography via transradial approach. | LitMetric

Background: The transradial approach is regarded as a useful vascular site for coronary procedures. The aim of this study was to test whether 4Fr catheters assisted by ACIST variable rate injector system can produce comparable angiographic quality and reduce the risk of radial artery injury compared to hand manifold 6 Fr catheters.

Methods: A total of 1816 patients were studied consecutively, among whom 856 patients received coronary angiography by 4 Fr catheters (4Fr group) and 960 patients by 6 Fr catheters (6Fr group). Angiographic and procedural characteristics were observed and recorded. The luminal inner radial arterial diameter before and after the procedure were collected.

Results: The baseline clinical characteristics were similar in both groups. There were no significant differences in procedure time, radiation dose and quality scores in both groups (P > 0.05), but more contrast media was delivered in the 6Fr group (P < 0.001). The mean radial arterial diameter six months after the procedure in the 6Fr group reduced significantly compared to that measured one day prior to the procedure (P < 0.001).

Conclusions: Coronary angiography using the 4Fr catheters with Acist power injection system can achieve an acceptable diagnostic quality while at the same time minimizing radial artery injury and contrast media consumption.

Download full-text PDF

Source

Publication Analysis

Top Keywords

4fr catheters
12
coronary angiography
12
6fr group
12
catheters acist
8
acist variable
8
variable rate
8
rate injector
8
injector system
8
hand manifold
8
transradial approach
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!