To avoid undesirable effects that sometimes result from current treatments for postpuncture femoral pseudoaneurysms, we developed a new technique involving compression assisted by removable coils. Using ultrasound-guided percutaneous puncture, an Inconel coil with synthetic microfibers is inserted in the pseudoaneurysm, leaving a part of the coil above the skin. Short-duration, ultrasound-guided compression is applied, taking advantage of the coil's thrombogenicity. Following occlusion, the coil is removed, leaving no residual foreign material. The technique was effective in the first patient treated and may minimize or obviate the adverse effects associated with current approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2010.07.011DOI Listing

Publication Analysis

Top Keywords

compression assisted
8
assisted removable
8
removable coils
8
femoral pseudoaneurysms
8
coils treatment
4
treatment iatrogenic
4
iatrogenic femoral
4
pseudoaneurysms avoid
4
avoid undesirable
4
undesirable effects
4

Similar Publications

Medical volume data are rapidly increasing, growing from gigabytes to petabytes, which presents significant challenges in organisation, storage, transmission, manipulation, and rendering. To address the challenges, we propose an end-to-end architecture for data compression, leveraging advanced deep learning technologies. This architecture consists of three key modules: downsampling, implicit neural representation (INR), and super-resolution (SR).

View Article and Find Full Text PDF

Safety and clinical efficacy of modified tracer fixation technique in orthopedic robot-assisted percutaneous vertebroplasty for Kümmell's disease.

J Robot Surg

January 2025

Department of Orthopaedics, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, 210028, Jiangsu, China.

The rising incidence of osteoporotic vertebral compression fractures (OVCF) has increased the demand for precise treatments like robot-assisted percutaneous vertebroplasty (PVP), especially for conditions like Kümmell's disease that require high surgical accuracy. However, the traditional tracer fixation method has certain limitations. This study aimed to compare the safety and clinical efficacy of a modified tracer fixation technique with the traditional fixation method in robot-assisted percutaneous vertebroplasty (PVP) for Kümmell's disease.

View Article and Find Full Text PDF

Extraction of compression indices from maternal-fetal heart rate simultaneous signals.

PLoS One

January 2025

MEDCIDS - Department of Community Medicine, Information and Decision in Health, Faculty of Medicine, University of Porto, Porto, Portugal.

Intrapartum asphyxia is responsible for approximately 900 000 deaths per year worldwide. These numbers show the urgency of investing in the quality of fetal health care. The heart rate signal is a complex signal and sometimes behaves unpredictably.

View Article and Find Full Text PDF

Introduction: There is a risk of iatrogenic vascular injuries during robotic-assisted laparoscopic excision of diaphragmatic endometriosis. Although studies are limited, the first reported case of a suprahepatic inferior vena cava (IVC) injury during robotic diaphragmatic endometriosis excision was successfully treated using a fibrin sealant patch, preventing exsanguination and conversion to laparotomy.

Case Description: A 36-year-old female with a history of recurrent catamenial pneumothorax and two prior video-assisted thoracoscopic surgeries to treat diaphragmatic endometriosis presented to our clinic with right-sided shoulder pain and a chest tube in place.

View Article and Find Full Text PDF

Correlations of facial soft tissue thicknesses with craniometric dimensions improve craniofacial identification estimates: Fact or fiction?

J Forensic Sci

December 2024

Laboratory for Human Craniofacial and Skeletal Identification (HuCS-ID Lab), School of Biomedical Sciences, The University of Queensland, Brisbane, Queensland, Australia.

Linear regression (LR) models that use cranial dimensions to estimate facial soft tissue thicknesses (FSTTs) have been posited by Simpson and Henneberg to assist craniofacial identification. For these regression equations to work well, the independent (craniometrics) and dependent (FSTTs) variables must be tightly correlated; however, such relationships have not been routinely demonstrated for adult humans. To examine the strength of these relationships further, this study employed magnetic resonance (MR) imaging to unambiguously measure cranial dimensions and FSTTs for 38 adult cadavers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!