Simultaneous assessment of liver volume and whole liver fat content: a step towards one-stop shop preoperative MRI protocol.

Eur Radiol

Department of Medical Imaging, University of Montreal and Centre de recherche, Centre hospitalier de l'Université de Montréal (CRCHUM), Hôpital Saint-Luc, 1058 rue Saint-Denis, Montréal, Québec, Canada.

Published: February 2011

Objective: The purpose of this study was to evaluate the ability of a whole liver volume (WLV) segmentation algorithm to measure fat fraction (FF).

Methods: Twenty consecutive patients with histologically proven fatty liver disease underwent dual-echo in-phase/out-of-phase MRI and magnetic resonance spectroscopy (MRS) at 1.5 T. Two readers independently performed semiautomatic 3D liver segmentation on the out-of-phase sequences using an active contour model. FF was calculated for voxels, segments and WLV. Segmentation inter-observer reproducibility was assessed by intra-class correlation coefficient (ICC) for WLV and FF. Fat fraction correlation and agreement as determined by histology, MRS and MRI were determined.

Results: ICC was 0.999 (95% CI: 0.999-1, P < 0.001) for WLV FF calculation and 0.996 (95% CI: 0.990-0.998, P < 0.001) for whole liver volume calculations. Strong correlations were found between FF measured by histology, MRS and WLV-MRI. A Bland-Altman analysis showed a good agreement between FF measured by MRS and WLV-MRI. No systematic variations of FF was found between segments when analyzed by ANOVA (F = 1.78, P = 0.096).

Conclusion: This study shows that a reproducible whole liver volume segmentation method to measure fat fraction can be performed. This strategy may be integrated to a "one-stop shop" protocol in liver surgery planning.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-010-1941-1DOI Listing

Publication Analysis

Top Keywords

liver volume
16
fat fraction
12
liver
8
wlv segmentation
8
measure fat
8
simultaneous assessment
4
assessment liver
4
volume
4
volume liver
4
fat
4

Similar Publications

Background: The current subclassification of steatotic liver disease (SLD) relies on validated questionnaires, such as Alcohol Use Disorders Identification Test (AUDIT) and Lifetime Drinking History (LDH), which, while useful, are impractical and lack precision for their use in routine clinical practice. Phosphatidylethanol (PEth) is a quantitative, objective alcohol biomarker with high sensitivity and specificity.

Aims: To assess the diagnostic accuracy of PEth for differentiating metabolic dysfunction and alcohol-associated liver disease (MetALD) from metabolic dysfunction-associated steatotic liver disease (MASLD) in a large, population-based, prospective, multiethnic cohort of individuals with overweight or obesity.

View Article and Find Full Text PDF

The impact of various neurodegenerative diseases on the retina has been investigated in recent years using optical coherence tomography (OCT). Epilepsy, classified as a neurodegenerative disorder, has been indicated to affect the structural integrity of the retina. Moreover, there is ongoing debate regarding the relative contribution of disease pathogenesis and the consumption of anti-epileptic drugs (AEDs) to these retinal changes.

View Article and Find Full Text PDF

Objective: This study aimed to introduce and evaluate a novel software-based system, BioTrace, designed for real-time monitoring of thermal ablation tissue damage during image-guided radiofrequency ablation for hepatocellular carcinoma (HCC).

Methods: BioTrace utilizes a proprietary algorithm to analyze the temporo-spatial behavior of thermal gas bubble activity during ablation, as seen in conventional B-mode ultrasound imaging. Its predictive accuracy was assessed by comparing the ablation zones it predicted with those annotated by radiologists using contrast-enhanced computed tomography (CECT) 24 hours post-treatment, considered the gold standard.

View Article and Find Full Text PDF

Background: Roux-en-Y gastric bypass may present long-term complications that require revisional surgery or even reversal to normal anatomy. Data on the indications, surgical technique, and outcomes of RYGB reversal remain scarce.

Methods: We identified 48 cases of RYGB reversals with complete 90-day follow-up within a multi-centric international retrospective database of elective secondary bariatric surgery.

View Article and Find Full Text PDF

Lung Clearance Index: A Sensitive Measure of Airway Function Improvement in Adolescents After Weight Loss from Bariatric Surgery.

Respir Med

January 2025

Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; Clalit Health Services, Dan Petah Tikva District, Petah Tikva, Israel. Electronic address:

Background: Morbid obesity in adolescents impacts respiratory function, often leading to reduced lung volume and obstructive ventilatory defects. However, standard spirometric values frequently remain within normal ranges.

Objectives: We hypothesized that Lung Clearance Index (LCI) is a more sensitive marker for detecting airway dysfunction in adolescents with morbid obesity than conventional lung function tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!