Background: Rotational angiography is one of the latest angiographic modalities to map the coronary venous tree anatomy. It provides a significant reduction in both contrast agent usage and radiation dose (up to 30%), without compromising the clinical utility of images. Hence, the present study was conducted to describe a new technique to minimize the amount of contrast media used during cardiac resynchronization therapy (CRT) implantation.
Method: The SL3 sheath was inserted into the right atrium via the femoral vein followed by withdrawal of the dilator. The tip of the sheath was manipulated to the vicinity of the coronary sinus (CS) ostium (OS). The CS was entered using a deflated balloon catheter. The sheath was then advanced gently beyond the CS OS. Occlusive venography was performed using 5-8 ml of contrast media in a rotational view starting from 45 degrees LAO to 0 degrees AP while holding the inflated balloon for a few seconds.
Result: Data from 30 consecutive patients who underwent CRT implantation were analyzed. The feasibility of rotational angiography, while occluding the CS with a specialized long, preshaped sheath and using an ordinary cath-lab imaging machine, was supported by the correctly delineated CS anatomy of all patients without any complications and death related to the placement of the CS catheters or sheaths. The mean contrast dose used for the entire procedure in all patients undergoing CRT was 14.76 +/- 6.8 ml.
Conclusion: Use of rotational CS occlusive venography utilizing an ordinary cath-lab X-ray machine minimizes the use of contrast media during CRT implantation without compromising the visualized anatomy.
Download full-text PDF |
Source |
---|
J Coll Physicians Surg Pak
January 2025
Department of Microbiology, Armed Forces Institute of Pathology / National University of Medical Sciences, Rawalpindi, Pakistan.
Objective: To evaluate Chicago Sky Blue (CSB) stain, Calcofluor white (CW) stain, and Potassium Hydroxide (KOH) mount for rapid diagnosis of dermatomycosis, using fungal culture as the gold standard.
Study Design: Cross-sectional analytical study. Place and Duration of the Study: This study was conducted in the Department of Microbiology, Armed Forces Institute of Pathology / National University of Medical Sciences, Rawalpindi, Pakistan, from July 2023 to February 2024.
Am Fam Physician
January 2025
University of Florida College of Medicine, Gainesville.
Jaundice is an indication of hyperbilirubinemia and is caused by derangements in bilirubin metabolism. It is typically apparent when serum bilirubin levels exceed 3 mg/dL and can indicate serious underlying disease of the liver or biliary tract. A comprehensive medical history, review of systems, and physical examination are essential for differentiating potential causes such as alcoholic liver disease, biliary strictures, choledocholithiasis, drug-induced liver injury, hemolysis, or hepatitis.
View Article and Find Full Text PDFLuminescence
January 2025
Pharmaceutical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt.
Two versatile yet simple methods, colorimetric and spectrofluorimetric, were utilized for the quantitation of nonchromophore neomycin using silver nanoparticles modified with fluorescein. Fluorescein was excited at 485 nm (emission at 515 nm); when it is deposited on the surface of silver nanoparticles, its fluorescence intensity at 515 nm is quenched. Neomycin restores the fluorescence level at 515 nm by displacing fluorescein from nanoparticle binding sites.
View Article and Find Full Text PDFJ Anim Sci
January 2025
Department of Animal and Food Sciences, University of Kentucky, Lexington, KY 40546, USA.
With the growing bourbon industry in the southeastern U.S. leading to increased production of liquid distillery byproducts, there is a pressing need to explore sustainable uses for whole stillage [containing residual grain (corn, rye, malted barley) and liquid after ethanol separation] in livestock nutrition.
View Article and Find Full Text PDFBr J Radiol
January 2025
Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Objectives: This study aimed to investigate the impact of changing inspiratory depth from end- to mid-inspiratory level on the iodine concentration of lung parenchyma and main pulmonary artery in dual-energy CT pulmonary angiography.
Methods: This retrospective study included patients who underwent dual-energy CT pulmonary angiography from July 2020 to June 2023. Patients were instructed to hold their breath at end- and mid-inspiratory levels before and after January 2022, respectively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!