A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of a posturographic approach to monitor sleepiness. | LitMetric

Sleepiness is a major risk factor in traffic- and occupational accidents. While sleepiness is a persistent concern, there is no convenient test to monitor impending levels of sleepiness. We show that force platform posturographic balance testing addresses this need because it estimates time awake (TA) accurately and precisely. Testing the TA is appropriate because TA drives the sleep homeostatic process, a component in sleepiness. With 12 subjects we evaluated the accuracy and precision of repeated estimates of TA. Our extended study design that allows evaluating the accuracy and precision of posturographic TA-estimates is new. First, we tested the subjects' balance every 2 h during 36 h of sustained wakefulness. This comprised the subjects' reference curves (balance as a function of known and increasing TA). Then, we tested the subjects' balance once a day over one week. We also tested the subjects' balance once a week over one month. Finally, to estimate the subjects' TA, we equated the balance scores with the scores in their reference curves. The accuracy of the estimates was 86%, and the precision was 97%. The high accuracy and precision of the estimates obtained with this one-month protocol validates the method of posturographic monitoring of sleepiness. So far, force platform posturographic balance testing has generally been used for clinical purposes, to quantify balance control and musculoskeletal performance. Our main result is that we now validated that balance testing provides accurate and precise estimates of TA, and hence, also provides an approach towards an automated monitor of sleepiness.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2010.08.013DOI Listing

Publication Analysis

Top Keywords

balance testing
12
accuracy precision
12
tested subjects'
12
subjects' balance
12
balance
9
monitor sleepiness
8
sleepiness force
8
force platform
8
platform posturographic
8
posturographic balance
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!