Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To compare the first throw tension holding properties of twisted versus straight first throws in two commonly used Oculoplastic braided absorbable sutures.
Design: An in-vitro experimental model.
Methods: Variable loads were applied to the first double throw of a surgical knot - either in straight-line configuration or twisting the knot using both 6/0 Polyglycolic acid (Dexon S) and 6/0 Polyglactin 910 (Coated Vicryl). Each suture was tested to the point of knot slipping and the critical tension recorded. Two variations of the experiment were undertaken: Experiment 1 - two metal loops were brought together by the test suture, experiment 2 - two strips of tissue (Permacol - cross-linked porcine dermal collagen) were brought together by the test suture.
Results: Experiment 1 straight: Polyglycolic acid 12.2g (11-13.5), Polyglactin-910 2.5 g (2.5- no range). Experiment 1 twisted: Polyglycolic acid 13.33 g (10-15), Polyglactin 910 3 g (2-5). Experiment 2 straight: Polyglycolic acid 33g (30-35), Polyglactin 910 25g (25 - no range). Experiment 2 twisted: Polyglycolic acid 35 (30-40), Polyglactin 910 25g (20-30).
Conclusions: Twisting the suture adds only a modest increase in first throw knot security. Polyglycolic acid (Dexon S) braided absorbable suture has significantly better first throw knot security when compared with Polyglactin-910 (coated Vicryl). This is an important property when suturing tissues under tension as it minimises slippage before the locking throw is tied.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3109/01676830.2010.487034 | DOI Listing |