A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Determination of phthalate esters in Baiyangdian Lake by solid phase microextraction and gas chromatography]. | LitMetric

A simple method based on solid-phase microextraction (SPME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the determination of trace amounts of phthalate esters (PAEs) in environment water samples. In this method, polydimethylsilane (PDMS) fiber was chosen to enrich the PAEs. The PAEs were extracted for 60 min using the PDMS fiber under stirring with a magnetic stir bar, after that the fiber was introduced into the GC injector port and the extract was desorbed at 250 degrees C for 4 min. Under the optimized conditions, 13 PAEs can be extracted completely and separated well. The limits of detection (LOD) were from 0.02 to 0. 83 microg/L (S/N = 3). The water samples collected from Baiyangdian lake were successfully analyzed using the proposed method, phthalic acid, bis-isobutyl ester (DIBP), phthalic acid, bis-butyl ester (DBP) and phthalic acid, bis-2-ethylhexyl ester (DEHP) were detected in all the samples. The spiked (2.5 microg/L and 5.0 microg/L) recoveries were in the range of 75.3-111.0% and the relative standard deviations (RSDs) were between 2.1% and 8.0% (n=3). The results showed that this would be a valuable method for PAEs analysis in environmental water samples.

Download full-text PDF

Source
http://dx.doi.org/10.3724/sp.j.1123.2010.00517DOI Listing

Publication Analysis

Top Keywords

water samples
12
phthalic acid
12
phthalate esters
8
baiyangdian lake
8
pdms fiber
8
paes extracted
8
paes
5
[determination phthalate
4
esters baiyangdian
4
lake solid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!