A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dysfunction of the posterior cruciate ligament in total knee arthroplasty. | LitMetric

Purpose: Total knee arthroplasty (TKA) is typically carried out either with retention (CR) of the posterior cruciate ligament (PCL) or with sacrifice of this ligament and implantation of a posterior stabilised (PS) prosthesis. This paper investigates a comparison of PCL function in knees treated for osteoarthritis with TKA where the PCL is preserved to those knees treated with TKA and posterior stabilisation.

Methods: One hundred and sixty-eight patients (232 knees) who had undergone TKA with either a PS or CR implant were included in the study. Clinical assessment included antero-posterior (AP) laxity and posterior sag assessment with an arthrometer.

Results: The mean AP laxity at 90° of flexion for CR TKAs was 6.5 mm (±3.1) and was the same [6.5 mm (±2.4)] as in the PS group. However, 56% of the PCL-preserved knees had a posterior sag of over 3 mm compared to 18% of the knees in the PS group. The American Knee Society Scores for either group showed that, although the mean function score was the same, the knee score was superior in the PS group (77 vs. 84). The range of motion was also superior in the PS group (111° vs. 105°).

Conclusion: The use of the PS prosthesis for TKA provides a more predictable outcome with regard to posterior sag and a better maximum flexion than a CR implant.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-010-1234-xDOI Listing

Publication Analysis

Top Keywords

posterior sag
12
posterior cruciate
8
cruciate ligament
8
total knee
8
knee arthroplasty
8
knees treated
8
superior group
8
posterior
6
tka
5
knees
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!