Comparison of plateletpheresis on three continuous flow cell separators.

Asian J Transfus Sci

Department of Transfusion Medicine, Tata Memorial Hospital, Mumbai - 400 012, India.

Published: July 2009

Introduction: Platelet concentrate (PC) remains one of the most important support measures in thrombocytopenic patients. An efficient cell separator is a prerequisite for an optimally functioning apheresis setup. Donor blood count may undergo a temporary reduction after the procedure.

Aim: The aim was to find the extent of reduction in donor blood count (hemoglobin, hematocrit, white blood cell, and platelet) after plateletpheresis and to evaluate the cell separator for collection efficiency, processing time, and leukoreduction.

Study Design And Methods: Two hundred and thirty seven procedures performed on the Amicus (N = 121), Fenwal CS-3000 Plus (N = 50) and Cobe spectra (N = 66) in a one year period were evaluated. The procedures performed on the continuous flow centrifugation (CFC) cell separators and donor blood counts (pre and post donation) done were included in the study.

Results: The percent reduction in hemoglobin (HB), hematocrit (HCT), white blood cell (WBC) and platelet count ((PLT ct) was 2.9, 3.1, 9, 30.7 (Mean, N = 237) respectively after the procedure. The post donation PLT ct reduced to < 100x109/L (range 80-100) in five donors (N = 5/237, Amicus). The pre donation PLT ct in them was 150-200x109/L. Collection efficiency (percent) of Amicus (79.3) was better as compared to the other two machines (CS: 62.5, Cobe: 57.5). PC collected on Cobe spectra had <1x106 WBC. The donor pre donation PLT levels had a positive correlation to the product PLT yield (r = 0.30, P = 0.000).

Conclusion: Monitoring donor blood counts helps to avoid pheresis induced adverse events. A cautious approach is necessary in donors whose pre donation PLT ct is 150-200x109/L. The main variable in PLT yield is donor PLT ct (pre donation). High collection efficiency is a direct measure of an optimally functioning cell separator.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2920476PMC
http://dx.doi.org/10.4103/0973-6247.53877DOI Listing

Publication Analysis

Top Keywords

donor blood
12
continuous flow
8
cell separators
8
cell separator
8
blood count
8
hemoglobin hematocrit
8
white blood
8
blood cell
8
collection efficiency
8
procedures performed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!