A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of a noninvasive expandable prosthesis in musculoskeletal oncology patients for the upper and lower limb. | LitMetric

The noninvasive expandable prosthesis is used for limb-salvage surgery following tumor resection in skeletally immature patients. The purpose of this retrospective study is to report our experience with the Repiphysis (Wright Medical Technology, Inc; Arlington, Tennessee) noninvasive expandable prosthesis for both the lower extremity and compassionate use in the upper extremity in 12 patients between 2003 and 2008. Twelve prostheses were implanted in 12 patients with an average follow-up of 38 months (range, 12-78 months). Nine patients underwent a total of 38 expansion procedures. Mean total expansion was 4.5 cm (range, 0.8-9.9 cm). No complications of lengthening occurred. Seven nononcologic complications were noted. One infection was reported in 12 patients. The mean MSTS score after rehabilitation was 24.5 (range, 13-30). The Repiphysis noninvasive prosthesis provides acceptable functional outcomes for both upper and lower extremity implantation and appears to have an advantage as compared to conventional expandable prosthetics, which require open procedures that can potentially increase the risk of infection from repeated hardware exposure.

Download full-text PDF

Source
http://dx.doi.org/10.3928/01477447-20100429-17DOI Listing

Publication Analysis

Top Keywords

noninvasive expandable
12
expandable prosthesis
12
upper lower
8
lower extremity
8
total expansion
8
patients
6
evaluation noninvasive
4
expandable
4
prosthesis
4
prosthesis musculoskeletal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!