This article presents 2 cases of foot drop after joint replacement surgery that presented after sequential compression device application. In both cases, intact peroneal nerve function was documented by the surgeon in the recovery room prior to sequential compression device application. We believe that excessive pressure over the superficial aspect of the peroneal nerve in conjunction with decreased pain stimulus from analgesia may have contributed to these complications. We maintain sequential compression devices are the current mechanical thromboprophylaxis of choice; however, 4 recommendations are made to minimize the chances of this potential complication. First, precise attention should be given to patients who are short statured, as these patients can be more susceptible to having a sequential compression device improperly placed over the peroneal nerve at the fibular neck. Second, we recommend different size options become more widely available to accommodate varying patient sizes such that placement of the device is ensured to be distal to the fibular neck. Third, when using sequential compression device brands that have hook and look fastener straps, the straps should not be tight on application and frequent skin checks should be made to look for signs of over-compression. Lastly, we recommend considering delaying postoperative application of the sequential compression device until resolution of sensation following spinal or epidural anesthetic.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3928/01477447-20100429-32 | DOI Listing |
Am J Community Psychol
January 2025
College of Social Work, University of South Carolina, Columbia, South Carolina, USA.
Combating the recent surge of anti-Asian racism requires a collective effort that includes the willingness of nontarget bystanders to intervene, but little is known about the circumstances under which they are willing to do so. The present qualitative study explores why non-Asian bystanders decide to intervene when they witness anti-Asian racism, and why, under other circumstances, they choose not to. Twenty semi-structured interviews were conducted with non-Asian college students who witnessed anti-Asian discrimination.
View Article and Find Full Text PDFMedical device-related pressure injuries (MDRPIs) pose a significant risk in the home health environment, where patients may lack continuous professional oversight. Devices commonly used in the home environment with the potential to cause a MDRPI include but are not limited to nasogastric tubes, feeding tubes, nasal cannulas, nasal cannula prongs, airway pressure masks, indwelling urinary catheters, sequential compression devices, dressings, bandages, and tracheostomies. When a medical device is used for an extended period, it can lead to unrelieved pressure or edema, cause friction and/or shearing that impairs sensation, reduces circulation, and alters the microclimate.
View Article and Find Full Text PDFFront Oncol
December 2024
Head and Neck Oncology Ward, West China Hospital of Sichuan University, Chengdu, China.
Background: Histiocytic sarcoma originates in various tissues, including the skin, lymph nodes, gastrointestinal tract, lungs, bone marrow, and central nervous system. Primary central nervous system histiocytic sarcoma (PCNSHS) is exceptionally rare, known for its aggressive behavior and poor prognosis. This report describes a case of PCNSHS in the cerebellum treated with surgery and radiotherapy.
View Article and Find Full Text PDFBiomater Adv
December 2024
State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China. Electronic address:
Hemorrhage caused by trauma is a global public health issue. While traditional cotton gauze compression is commonly used for hemostasis, its efficacy is limited in severe hemorrhage cases. Herein, we developed a gauze with Janus wettability (JW-G).
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Trauma and Microreconstructive Surgery, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, 830054, China.
Background: The purpose of this study was to report the clinical and psychological outcomes of using a locking compression plate (LCP) as a sequential external fixator following the distraction phase in the treatment of tibial bone defects caused by fracture-related infection (FRI).
Methods: We retrospectively analyzed the clinical records and consecutive X-ray images of patients with tibial bone defects who were treated with an LCP as a sequential external fixator following the distraction phase, between June 2017 and December 2022. The ASAMI criteria were applied to assess the bone and functional outcomes, and postoperative complications were evaluated by using the Paley classification.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!