Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The relative oxygen saturation of hemoglobin and the rate of perfusion are important physiological quantities, particularly in organs such as skeletal muscle, in which oxygen delivery and use are tightly coupled. The purpose of this study was to demonstrate the image-based calculation of the relative oxygen saturation of hemoglobin and quantification of perfusion in skeletal muscle during isometric contractions. This was accomplished by establishing an empirical relationship between the rate of radiofrequency-reversible dephasing and near-infrared spectroscopy-observed oxyhemoglobin saturation (relative oxygen saturation of hemoglobin) under conditions of arterial occlusion and constant blood volume. A calibration curve was generated and used to calculate the relative oxygen saturation of hemoglobin from radiofrequency-reversible dephasing changes measured during contraction. Twelve young healthy subjects underwent 300 s of arterial occlusion and performed isometric contractions of the dorsiflexors at 30% of maximal contraction for 120 s. Muscle perfusion was quantified during contraction by arterial spin labeling and measures of muscle T(1). Comparisons between the relative oxygen saturation of hemoglobin values predicted from radiofrequency-reversible dephasing and that measured by near-infrared spectroscopy revealed no differences between methods (P = 0.760). Muscle perfusion reached a value of 34.7 mL 100 g(-1) min(-1) during contraction. These measurements hold future promise in measuring muscle oxygen consumption in healthy and diseased skeletal muscle.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4437700 | PMC |
http://dx.doi.org/10.1002/mrm.22475 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!