What is the functional significance of nondominant arm tremor in essential tremor?

Mov Disord

GH Sergievsky Center, College of Physicians and Surgeons, Columbia University, New York, New York, USA.

Published: November 2010

Tremor in the dominant arm is often the focus of clinical attention in essential tremor (ET) yet many daily activities require both arms. The functional relevance of nondominant arm tremor has rarely been studied. In 181 right-handed patients with ET, action tremor in each arm was rated using a clinical rating scale. Tremor disability was self-reported and a performance-based test of function was administered. Independently of tremor on the right, greater tremor severity on the left was associated with greater self-reported disability (P = 0.02) and greater performance-based dysfunction (P < 0.001). In 5.0% of patients, tremor was largely restricted to the nondominant arm. Nondominant arm tremor, independent of dominant arm tremor, had a significant functional correlate, contributing to both greater perceived and greater observable functional difficulty. In 5% of patients, tremor in the nondominant arm was the likely motivator for seeking care, which is another indication of its functional significance. © 2010 Movement Disorder Society.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2978780PMC
http://dx.doi.org/10.1002/mds.23284DOI Listing

Publication Analysis

Top Keywords

nondominant arm
20
arm tremor
16
tremor
12
functional significance
8
arm
8
dominant arm
8
patients tremor
8
functional
5
nondominant
5
greater
5

Similar Publications

Introduction: The bilateral deficit (BLD) is a reduction in the amount of force during a bilateral task vs. the total force from the unilateral limbs performing the same task. We quantified the BLD during an upper body Wingate Anaerobic Test (WAnT) and evaluated the influence of sex and load on the BLD in force.

View Article and Find Full Text PDF

Background: Musculoskeletal adaptations are common in overhead athletes. As they also are involved in injury prevention, there has been an increase in their evaluation through shoulder screening over the last years. However, for some evaluations, and especially for functional testing, there is a lack of normative values, which limits the interpretation of the values measured.

View Article and Find Full Text PDF

Objectives: Although exercise-induced vascular adaptations have been extensively reported in racket sports athletes, the applicability of these findings to athletes in other overhead sports is unclear. This study aimed to investigate exercise-induced vascular adaptations in college male baseball players. Furthermore, since the training frequency of the upper arm may differ by baseball playing position, this study also focused on playing position-specific differences in brachial arterial adaptations.

View Article and Find Full Text PDF

Digital Health Technologies for Optimising Treatment and Rehabilitation Following Surgery: Device-Based Measurement of Sling Posture and Adherence.

Sensors (Basel)

December 2024

Assessment of Movement Behaviours (AMBer), Leicester Lifestyle and Health Research Group, Diabetes Research Centre, University of Leicester, Leicester LE5 4PW, UK.

Background: Following shoulder surgery, controlled and protected mobilisation for an appropriate duration is crucial for appropriate recovery. However, methods for objective assessment of sling wear and use in everyday living are currently lacking. In this pilot study, we aim to determine if a sling-embedded triaxial accelerometer and/or wrist-worn sensor can be used to quantify arm posture during sling wear and adherence to sling wear.

View Article and Find Full Text PDF

Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study.

JMIR Form Res

January 2025

Department of Biomedical Informatics, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.

Background: The iAide2 (Tokai) physical activity monitoring system includes diverse measurements and wireless features useful to researchers. The iAide2's sleep measurement capabilities have not been compared to validated sleep measurement standards in any published work.

Objective: We aimed to assess the iAide2's sleep duration and total sleep time (TST) measurement performance and perform calibration if needed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!