AI Article Synopsis

Article Abstract

The three transport equation optical properties, the absorption coefficient, the scattering coefficient, and the average cosine of the scattering angle, or anisotropy factor have been measured (at 632.8 nm) for canine myocardium after it is heated in a water bath at room temperature and at 37-75 degrees C for 1000 s. The measurement system was a double integrating sphere with collimated light and utilized the adding-doubling solution to the equation of radiative transfer. The absorption coefficient (room temperature control, 2.0 +/- 0.4 cm(-1)) began to increase and the anisotropy factor (room temperature control, 0.93 +/- 0.02) to decrease at above 45 degrees C. At 75 degrees C the changes were significant at the p < 0.0005 level (absorption, 4.5 +/- 1.3 cm(-1); anisotropy, 0.78 +/- 0.05). There was no significant change in the scattering coefficient (room temperature controls, 161 +/- 33 cm(-1)).

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.32.000367DOI Listing

Publication Analysis

Top Keywords

room temperature
16
+/- cm-1
12
optical properties
8
absorption coefficient
8
scattering coefficient
8
anisotropy factor
8
coefficient room
8
temperature control
8
+/-
5
changes optical
4

Similar Publications

Ceramic aerogels are promising high-temperature thermal insulation materials due to their outstanding thermal stability and oxidation resistance. However, restricted by nanoparticle-assembled network structures, conventional ceramic aerogels commonly suffer from inherent brittleness, volume shrinkage, and structural collapse at high temperatures. Here, to overcome such obstacles, 3D ultralight and highly porous carbon tube foams (CTFs) were designed and synthesized as the carbonaceous precursors, where melamine foams were used as the sacrificial templates to form the hollow and thin-wall network structures in the CTFs (density: ∼4.

View Article and Find Full Text PDF

Rapid fabrication and dissolution of pressed Ni/Mg matrix targets for Co production.

EJNMMI Radiopharm Chem

January 2025

Department of Nuclear Medicine and Medical Physics, Karolinska University Hospital, Stockholm, 171 76, Sweden.

Background: Beyond the use of conventional short-lived PET radionuclides, there is a growing interest in tracking larger biomolecules and exploring radiotheranostic applications. One promising option for imaging medium-sized molecules and peptides is ⁵⁵Co (T₁/₂ = 17.5 h, β⁺ = 76%), which enables imaging of new and already established tracers with blood circulation of several hours.

View Article and Find Full Text PDF

Background: Blood-based biomarkers, especially P-tau217, have been gaining interest as diagnostic tools to measure Alzheimer disease (AD) pathology.

Methods: We developed a plasma P-tau217 chemiluminescent immunoassay using 4G10E2 and IBA493 as antibodies, a synthetic tau peptide as calibrator, and the Quanterix SP-X imager. Analytical validation performed in a College of American Pathologists-accredited CLIA laboratory involved multiple kit lots, operators, timepoints, and imagers.

View Article and Find Full Text PDF

Characterization of a simple gas expansion ion source for intense pulses of subthermal molecular ions.

Rev Sci Instrum

January 2025

Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg, Germany.

We describe a simple gas expansion ion source based on static discharge voltages and a commercially available pulsed valve. The discharge is initiated by the gas pulse itself between two high voltage electrodes, without the need for fast voltage switches or complex timing schemes. The ion source very reliably produces intense bursts of molecular ions (with currents exceeding 100 μA during the pulse-on phase) with only minor pulse-to-pulse variations in intensity and pulse shape.

View Article and Find Full Text PDF

From molecular dynamics (MD) simulations of melt-quenching and thermal aging procedures in pure Ag, Cu, Ag-Cu binary alloys, and Cu-Zr binary alloys, we have identified two distinct amorphous phases for a metastable undercooled liquid: the homogeneous L-phase with low shear rigidity and the heterogenous G-phase with much higher shear rigidity and a heterogeneity length scale Λ. Here, we examine two-phase equilibration studies showing that the G-phase melts to form the L-phase above ~1,000 K, which then transforms to form the crystal (X) phase; however, below the melting point of the G-Phase (~990 K), the X- and G-phases do not transform into each other. We suggest the presence of a G-phase is likely responsible for embrittlement often observed in metallic glasses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!