A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel electrochemical sensor based on nano-structured film electrode for monitoring nitric oxide in living tissues. | LitMetric

A novel electrochemical sensor based on nano-structured film electrode for monitoring nitric oxide in living tissues.

Talanta

Institute of Pharmaceutical Analysis, College of pharmacy, Wuhan University, Donghu Road No 185, Wuhan 430071, China.

Published: September 2010

A sensor exhibited high sensitivity and good selectivity for determination of nitric oxide (NO) was fabricated. The sensor was constructured by coating Nafion/multi-walled carbon nanoubes-chitosan-gold nanoparticles (Nafion/MWNTs-CS-AuNPs) film on glassy carbon electrode (GCE). Several key parameters affecting on the electrochemical response were optimized, such as the film thickness, applied potential and volume of Nafion. The sensor showed good linear relationship with the NO concentration in the range of 1.90 x 10(-8) to 5.40 x 10(-5)M and with the detection limit of 7.60 x 10(-9)M (S/N=3). Finally, the sensor was successfully applied to the monitoring of NO release from living tissues, including mouse kidney, heart, spleen and liver (a slice). NO release at micro-molar level can be detected while the NO donor l-arginine (l-Arg), nitroglycerin (GTN) and aspirin (ASA) was present. It was interestedly found that the capacities to induce NO generation were in the order of GTN>ASA>l-Arg when these stimulants were converted to the same concentration. In addition, the NO release is associated with the functional groups in these donors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2010.06.035DOI Listing

Publication Analysis

Top Keywords

nitric oxide
8
living tissues
8
sensor
5
novel electrochemical
4
electrochemical sensor
4
sensor based
4
based nano-structured
4
nano-structured film
4
film electrode
4
electrode monitoring
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!