A new type of blood pump was tested in calves for 6 hours. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotating on an eccentric shaft, describes a trochoidal path, thus creating a gap seal, the gap measuring a constant 10-35 microns. The pump is driven by a watercooled DC motor. For right ventricular assist, a cannula is inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assists. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 31 at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hours, and returned to 16 mg/dl after 6 hours. From these preliminary results it is concluded that this new rotary blood pump may be suitable as a circulatory assist device.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/bmte.1990.35.12.290 | DOI Listing |
JACC Case Rep
January 2025
Allina Health Minneapolis Heart Institute, Abbott Northwestern Hospital, Minneapolis, Minnesota, USA.
We present a first in human experience of transseptal balloon-assisted translocation of a mitral anterior leaflet (BATMAN) to facilitate transcatheter mitral valve replacement in a patient with severe mitral annular calcification who was at high risk of left ventricular outflow tract obstruction.
View Article and Find Full Text PDFCASE (Phila)
December 2024
Department of Anesthesiology, Hackensack University Medical Center, Hackensack, New Jersey.
J Cardiothorac Vasc Anesth
January 2025
Department of Anesthesia, Cardiothoracic Surgery/Cardiac ICU Section, Heart Hospital, Hamad Medical Corporation, Doha, Qatar; Department of Critical Care Medicine, Beni Suef University, Egypt; Weill Cornell Medical College, Doha, Qatar.
Objective: The use of an intra-aortic balloon pump (IABP) has been suggested to unload the left ventricle while on venoarterial extracorporeal membrane oxygenation (VA-ECMO) for cardiogenic shock (CS), leading to possibly improved in-hospital mortality. However, the predictors of mortality on dual mechanical circulatory support have not yet been evaluated, especially in real-world clinical settings. Therefore, a case-control study was conducted to determine the rate of all-cause mortality associated with VA-ECMO use regardless of left ventricular (LV) unloading, and with early LV unloading in the setting of CS, and to identify the predictors of mortality associated with VA-ECMO, with concurrent early LV unloading.
View Article and Find Full Text PDFMultimed Man Cardiothorac Surg
January 2025
Congenital Heart Center, Division of Cardiovascular Surgery, Department of Surgery, University of Florida, Gainesville, FL, USA.
The Berlin Heart EXCOR is a pulsatile paracorporeal ventricular assist device (VAD) for neonates, infants, children and adults with congenital or acquired severe ventricular dysfunction. Berlin Heart EXCOR VADs are routinely used as either a bridge to a cardiac transplantation, or occasionally as a bridge to ventricular recovery. Our programmatic philosophy is to bridge neonates and infants with functionally univentricular ductal-dependent systemic circulation or functionally univentricular ductal-dependent pulmonary circulation who are at high risk for staged palliation because of important cardiac risk factors with a single-ventricle VAD (sVAD) as a bridge to a cardiac transplant.
View Article and Find Full Text PDFCurr Opin Cardiol
January 2025
Division of Cardiology, University of Ottawa Heart Institute, University of Ottawa, Faculty of Medicine, Tier 1 Clinical Research Chair in Cardiac Electrophysiology, Ottawa, ON, Canada.
Purpose Of Review: This review presents contemporary data on epidemiology, common presentations, investigations and diagnostic algorithms, treatment and prognosis. It particularly focuses on topics of most relevance to heart failure specialists, including what left ventricle (LV) function changes can be expected after treatment and outcomes to all standard and advanced heart failure therapies.
Recent Findings: Around 5% of sarcoidosis patients have clinically manifest cardiac sarcoidosis (CS), presenting with significant arrhythmias (such as conduction disturbances and ventricular arrhythmias) or newly developed unexplained heart failure.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!