A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints. | LitMetric

(153)Sm-EDTMP is a radiopharmaceutical composed of EDTMP (ethylenediamine-tetramethylenephosphonate) and Samarium-153 [1]. (153)Sm-EDTMP has an affinity for skeletal tissue and concentrates in areas with increased bone turnover; thus, it is successfully used in relieving pain related to diffuse bone metastases [1]. The manufacturing process of (153)Sm-EDTMP leads to contamination with (154)Eu (Europium-154) [2]. A previous study only alluded to the retention of (154)Eu in the bones after receiving treatment with (153)Sm-EDTMP [2]. Activation of the alarm at security checkpoints after (153)Sm-EDTMP therapy has not been previously reported. Two out of 15 patients who received (153)Sm-EDTMP at Roger Maris Cancer Center (Fargo, N. Dak., USA) activated the radiation activity sensors while passing through checkpoints; one at a US airport and the other while crossing the American-Canadian border. We assume that the (154)Eu which remained in the patients' bones activated the sensors. METHODS: In order to investigate this hypothesis, we obtained the consent from 3 of our 15 patients who received (153)Sm-EDTMP within the previous 4 months to 2 years, including the patient who had activated the radiation alarm at the airport. The patients were scanned with a handheld detector and a gamma camera for energies from 511 keV to 1.3 MeV. RESULTS: All three patients exhibited identical spectral images, and further analysis showed that the observed spectra are the result of (154)Eu emissions. CONCLUSION: Depending on the detection thresholds and windows used by local and federal authorities, the remaining activity of (154)Eu retained in patients who received (153)Sm-EDTMP could be sufficient enough to increase the count rates above background levels and activate the sensors. At Roger Maris Cancer Center, patients are now informed of the potential consequences of (153)Sm-EDTMP therapy prior to initiating treatment. In addition, patients treated with (153)Sm-EDTMP at Roger Maris Cancer Center receive laminated cards stating the date and the dose of treatment, as well as a statement that the holder may activate the alarm at the security checkpoints.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2918865PMC
http://dx.doi.org/10.1159/000235809DOI Listing

Publication Analysis

Top Keywords

security checkpoints
12
patients received
12
received 153sm-edtmp
12
roger maris
12
maris cancer
12
cancer center
12
153sm-edtmp
10
radiation alarm
8
checkpoints 153sm-edtmp
8
alarm security
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!