A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Balloon aortic valvuloplasty for aortic stenosis using a novel percutaneous dilation catheter and power injector. | LitMetric

Calcific aortic stenosis is the most common valvular heart disease in the Western world. Although definitive treatment is valve replacement, many patients are not replacement candidates due to high surgical risk from older age and comorbid illness or lack of desire for a surgical or replacement procedure. Percutaneous balloon aortic valvuloplasty (BAV) is an option for palliative treatment in nonsurgical patients, although this procedure is complicated during the immediate postprocedure period by bleeding requiring transfusion for about 1 in 5 patients and subsequent restenosis. This report describes BAV using a smaller profile balloon designed to withstand higher pressures, rapidly inflated with a power injector. Twenty consecutive high-risk patients with severe aortic stenosis were treated. In all cases, New York Heart Association (NYHA) class improved from IV before BAV to I or II at 30 days follow-up. Six-month posttreatment follow-up data were available for 19 of 20 patients: 15 patients were either NYHA class I or II, 1 patient was class III, and 3 deaths occurred unrelated to aortic stenosis. One patient was lost to follow-up. Average systolic gradient peak-to-peak pressure decreased by 40.0% (range 18.0-70.0%) and mean gradient decreased by 30.0% (range 13.7-70.8%). Aortic valve area increased from 0.59 ± 0.16 cm(2) to 0.92 ± 0.23 cm(2), representing a mean increase of 30.0% (range 7.8%-58.2%). There were no significant bleeding complications. The only procedural complication was a single case of pericardial tamponade. There were no other complications during the first 24 hours post-BAV. These data support that the reported BAV technique may offer an effective alternative for patients with severe aortic stenosis who are not surgical candidates or prefer to avoid aortic valve replacement.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8183.2010.00594.xDOI Listing

Publication Analysis

Top Keywords

aortic stenosis
20
balloon aortic
8
aortic valvuloplasty
8
aortic
8
power injector
8
valve replacement
8
patients severe
8
severe aortic
8
nyha class
8
300% range
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!