Outcome of orthopedic implant infections due to different staphylococci.

Int J Infect Dis

Orthopedic Surgery Service, Geneva University Hospitals and Faculty of Medicine, University of Geneva, 24 Rue Micheli-du-Crest, 1211 Geneva 14, Switzerland.

Published: October 2010

Background: Comparisons of different staphylococci in orthopedic implant infections have rarely been reported. In this study we assessed total joint arthroplasty infections and other orthopedic implant infections due to methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant Staphylococcus aureus (MRSA), and coagulase-negative staphylococci (CoNS).

Methods: This was a retrospective study performed at the Geneva University Hospitals for the period January 1996 to June 2008.

Results: There were 44 infections due to MRSA, 58 due to MSSA, and 61 due to CoNS. Overall cure was achieved in 57% (25/44) of MRSA infections, 72% (42/58) of MSSA infections, and 82% (50/61) of CoNS infections, after a minimum follow-up of 1 year. In the subgroup of arthroplasty infections only, cure was achieved in 39% (7/18) of MRSA, 60% (15/25) of MSSA, and 77% (30/39) of CoNS episodes. In multivariate analysis, arthroplasty (odds ratio (OR) 0.2, 95% confidence interval (95% CI) 0.1-0.6) and MRSA infections (OR 0.3, 95% CI 0.1-0.9) were inversely associated with overall cure for all implants. CoNS infection (OR 3.0, 95% CI 1.2-8.0) and the insertion of a new implant (OR 4.5, 95% CI 1.6-13.1) were associated with higher cure results. Methicillin resistance, immunosuppression, sex, age, duration of antibiotic therapy, one-stage revision, rifampin use, and total number of surgical interventions did not influence cure. MRSA-infected patients had more post-infection sequelae than patients with MSSA or CoNS (Chi-square test 13/44 vs. 93/119, OR 3.4, 95% CI 1.3-8.9, p=0.004).

Conclusions: In orthopedic implant infections, S. aureus is more virulent than CoNS. MRSA has the worst outcome and CoNS the best.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijid.2010.05.014DOI Listing

Publication Analysis

Top Keywords

orthopedic implant
16
implant infections
16
infections
11
arthroplasty infections
8
staphylococcus aureus
8
mssa cons
8
cure achieved
8
mrsa infections
8
cons
7
mrsa
6

Similar Publications

Background And Objective: The global average life expectancy has been increasing steadily as the quality of healthcare continues to improve. However, there is a paucity of data looking at surgical fixation of thoracolumbar spine fractures in patients ≥80 years (super-elderly). Aim of this study is to look at whether there is higher rate of complications from surgical fixation of thoracolumbar fractures in this group of patients.

View Article and Find Full Text PDF

Distal femoral replacement (DFR) with megaprostheses is a salvage revision total knee arthroplasty (rTKA) procedure indicated in cases with massive bone defects in the distal femur. As long as these implants achieve fixation only in the diaphysis, the high aseptic loosening rate reported in some series is probably related to a lack of rotational stability. Two patients with extensive distal femoral bone defects with preservation of the metaphyseal-diaphyseal junction underwent rTKA.

View Article and Find Full Text PDF

Introduction: Breast surgeries are classified as clean procedures associated with a lower risk of post-operative infections; however, the reported infection rates post-breast surgeries are still significantly high. Surgical site infections (SSIs) are indeed one of the most common and serious complications following breast surgery.

Methodology: A retrospective study assessed the rate of SSIs post-breast reconstructive surgery after the implementation of the infection control protocol at James Cook University Hospital and Friarage Hospital from December 2022 to June 2024.

View Article and Find Full Text PDF

Hybrid additive manufacturing for Zn-Mg casting for biomedical application.

In Vitro Model

December 2024

Department of Industrial and Manufacturing Engineering, Pennsylvania State University, State College, University Park, PA USA.

Zinc (Zn) and its alloys have been the focus of recent materials and manufacturing research for orthopaedic implants due to their favorable characteristics including desirable mechanical strength, biodegradability, and biocompatibility. In this research, a novel process involving additive manufacturing (AM) augmented casting was employed to fabricate zinc-magnesium (Zn-0.8 Mg) artifacts with surface lattices composed of triply periodic minimal surfaces (TPMS), specifically gyroid.

View Article and Find Full Text PDF

A novel application perspective of the clinical-used drug verapamil on osteoporosis via targeting .

J Orthop Translat

January 2025

Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, People's Republic of China.

Background: RANKL and SCLEROSTIN antibodies have provided a strong effective choice for treating osteoporosis in the past years, which suggested novel molecular target identification and therapeutic strategies development are important for the treatment of osteoporosis. The therapeutic effect of verapamil, a drug previously used for cardiovascular diseases, on diabetes was due to the inhibition of TXNIP expression, which has also been reported as a target in mice osteoporosis. Whether verapamil-inhibited TXNIP expression is related to osteoporosis and how it works on the molecular level is worthy to be explored.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!