In western countries, the use of a balloon-expandable covered stent is recommended for the treatment of native coarctation of the aorta (CoA) in adult patients because endovascular bare stents cannot completely prevent complications such as aneurysms or aortic rupture. However, such a product that is appropriate and officially approved is not available in Japan. We developed and used a handmade balloon-expandable covered stent in a 32-year-old patient with native CoA and achieved a good outcome. A Palmaz-Schatz stent (XL 10-series 4010; Johnson & Johnson, Warren, NJ, USA) was covered with an Ube woven-graft (WST series; 18 mm across; Ube Junken Medical, Tokyo, Japan). Because the stent shortens when dilated, one end of the graft was firmly sutured to one end of the stent, whereas the other end of the graft was stitched loosely to the other end of the stent so that it could slide along the struts of the stent to accommodate foreshortening. After meticulous in vitro simulations, the covered stent was implanted with right ventricular overdrive pacing. No complications were observed, and the pressure gradient disappeared. These results indicate that angioplasty using a balloon-expandable covered stent is highly safe and effective for correcting native CoA in adult patients and hopefully in children.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jjcc.2010.06.005DOI Listing

Publication Analysis

Top Keywords

covered stent
20
balloon-expandable covered
16
stent
10
native coarctation
8
coarctation aorta
8
coa adult
8
adult patients
8
native coa
8
covered
6
hand-made balloon-expandable
4

Similar Publications

Despite the unique properties of clay nanocomposites for cardiovascular applications, there are few data on the hemocompatibility of these nanomaterials. This study represents the first comprehensive investigation of the hemo/biocompatibility of clay nanocomposites . Nanocomposite coatings of polylactic acid (PLA)-polyethylene glycol (3 wt %)-Cloisite20A nanoclay (3 wt %) were produced using electrospraying technique as potential drug-eluting stent (DES) coatings.

View Article and Find Full Text PDF

Percutaneous Coronary Intervention (PCI) is a treatment method that involves reopening narrowed arteries with a balloon catheter that delivers a cylindrical, mesh-shaped implant device to the site of the stenosis. Currently, by applying a coating to a bare metal stent (BMS) surface to improve biocompatibility, the main risks after PCI, such as restenosis and thrombosis, are reduced while maintaining the basic requirements for the mechanical behavior of the stent itself. In this work, for the first time, the development and optimization process of the spatial structure of the Co-Cr stent (L-605) with a graphene-based coating using cold-wall chemical vapor deposition (CW-CVD) to ensure uniform coverage of the implant was attempted.

View Article and Find Full Text PDF

Introduction: Since the mid-1900s, techniques in the repair of aortic arch and thoracoabdominal aortic pathologies have drastically evolved. Open aortic surgical repair was once the sole option for both simple and complex aneurysmal degeneration. Today, a number of minimally invasive and hybrid approaches are now available to assist both the surgeon and patient in tackling this challenging problem.

View Article and Find Full Text PDF

With an increasingly aging population, both end-stage renal disease and peripheral artery disease become more prevalent. Peripheral artery disease is increasingly treated with endovascular procedures. Endovascular stenting of the external iliac artery (EIA) is often considered a contraindication for kidney transplantation, as clamping of the artery could result in possible injuring of the stent.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!