Serologic testing results are one of the major reasons for discarding donor corneas. This study assessed the prevalence of serologic markers and the times of preanalytic steps. The prevalence of serologic markers in 705 cornea donors of the Lorraine region was studied. One hundred forty-one (20%) corneas were discarded on the basis of serologic testing. In a subsample of 180 consecutive cornea donors, data concerning the time of death, sampling, and serology testing were collected. When the time between death and sampling did not exceed 8 h (n = 122), immediate decantation (separation of serum from clot) led to less discarding of corneas than delayed decantation (2/46 [4.3%] discarded in the group with immediate decantation versus 13/76 [17.1%] discarded in the group with delayed decantation [P = 0.038]). For blood samples collected within 8 h of death, the rate of reactive results is significantly lower if samples are immediately decanted.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.diagmicrobio.2010.05.004 | DOI Listing |
Transplant Rev (Orlando)
January 2025
Laboratory of Ocular Immunology, Transplantation, and Regeneration, Schepens Eye Research Institute of Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA. Electronic address:
Immunology depends on maintaining a delicate balance within the human body, and disruptions can result in conditions such as autoimmune diseases, immunodeficiencies, and hypersensitivity reactions. This balance is especially crucial in transplantation immunology, where one of the primary challenges is preventing graft rejection. Such rejection can lead to organ failure, increased patient mortality, and higher healthcare costs due to the limited availability of donor tissues relative to patient needs.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
January 2025
Harry S. Truman Memorial Veterans' Hospital, Columbia, Missouri, United States.
Purpose: Sulfur mustard gas (SM) exposure to eyes causes multiple corneal injuries including stromal cell loss in vivo. However, mechanisms mediating stromal cell loss/death remains elusive. This study sought to test the novel hypothesis that SM-induced toxicity to human corneal stromal fibroblasts involves ferroptosis mechanism via p38 MAPK signaling.
View Article and Find Full Text PDFEur J Ophthalmol
January 2025
Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, Florida, USA.
Background: To describe a case of guttae recurrence in bilateral corneal grafts in a patient with a known diagnosis of Fuchs endothelial dystrophy, more than three decades following penetrating keratoplasty.
Methods: Case Report.
Results: A 79-year-old White woman presented with declining vision, right eye worse than the left.
Invest Ophthalmol Vis Sci
January 2025
Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Congenital Aniridia Research, Homburg/Saar, Germany, Saarland University, Homburg/Saar, Germany.
Purpose: This study evaluates the microRNA (miRNA) expression profile in primary limbal epithelial cells (pLECs) of patients with aniridia.
Methods: Primary human LECs were sampled and isolated from 10 patients with aniridia and 10 healthy donors. The miRNA profile was analyzed using miRNA microarrays.
Cell Tissue Bank
January 2025
Academic Ophthalmology, Mental Health and Clinical Neurosciences, School of Medicine, University of Nottingham, Nottingham, UK.
Globally there is a shortage of available donor corneas with only 1 cornea available for every 70 needed. A large limitation to corneal transplant surgery is access to quality donor tissue due to inadequate eye donation services and infrastructure in many countries, compounded by the fact that there are few available long-term storage solutions for effectively preserving spare donor corneas collected in countries with a surplus. In this study, we describe a novel technology termed low-temperature vacuum evaporation (LTVE) that can effectively dry-preserve surplus donor corneal tissue, allowing it to be stored for approximately 5 years, shipped at room temperature, and stored on hospital shelves before rehydration prior to ophthalmic surgery.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!