Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-010-1269-6DOI Listing

Publication Analysis

Top Keywords

implementation colonoscopic
4
colonoscopic process
4
process measures
4
measures improve
4
improve quality?
4
implementation
1
process
1
measures
1
improve
1
quality?
1

Similar Publications

Optical diagnosis poses challenges to implementation of "resect and discard" strategies. This study aimed to assess the feasibility and performance of a new commercially available system for colorectal polyps. Nine expert endoscopists in three centers performed colonoscopies using artificial intelligence-equipped colonoscopes (CAD EYE, Fujifilm).

View Article and Find Full Text PDF

Endoscope reprocessing: Retrospective analysis of 90,311 samples.

Endosc Int Open

March 2023

Eurofins Biotech Germande, Medical Device Testing, Aix-en-Provence, France.

The contamination level of ready-to-use endoscopes published in the literature varies from 0.4 % to 49.0 %.

View Article and Find Full Text PDF

Rare case of rectal perforation by an intrauterine device: Case report and review of the literature.

Int J Surg Case Rep

October 2022

Department of Surgery, Jaber Al-Ahmad Hospital, Kuwait; Department of Surgery, Faculty of Medicine, Kuwait University, Kuwait.

Introduction And Importance: Intrauterine devices (IUDs) are safe, highly effective and reversible forms of contraception. Reliance on IUD has been increasing and as such, it is the responsibility of the healthcare provider to be aware of the complications associated with it. IUD rectal migration is one of the rare but serious complications that may lead to detrimental sequelae.

View Article and Find Full Text PDF

Purpose: Lynch syndrome-related colorectal cancer (CRC) risk substantially varies by mismatch repair (MMR) gene. We evaluated the health impact and cost-effectiveness of MMR gene-tailored colonoscopic surveillance.

Methods: We first estimated sex- and MMR gene-specific cumulative lifetime risk of first CRC without colonoscopic surveillance using an optimization algorithm.

View Article and Find Full Text PDF

Introduction: Computer-aided detection (CADe) helps increase colonoscopic polyp detection. However, little is known about other performance metrics like the number and duration of false-positive (FP) activations or how stable the detection of a polyp is.

Methods: 111 colonoscopy videos with total 1,793,371 frames were analyzed on a frame-by-frame basis using a commercially available CADe system (GI-Genius, Medtronic Inc.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!