Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Seven Angus and six Brangus steers averaging 225 and 245 kg, respectively, were assigned randomly to zeranol (36 mg) implant (I) and no implant (NI) treatments. Steers had ad libitum access to a corn silage diet plus .68 kg of a soybean meal-based supplement fed daily. Steers were bled via jugular catheters on d 0, 28, 56, and 84 at 15-min intervals for 4 h before and 4 h after feeding. Concentrations of growth hormone (GH), insulin (INS), triiodothyronine (T3), thyroxine (T4), and glucose were determined. Whole-body protein and fat contents were monitored. A breed x I interaction (for d 56 to 84 and d 0 to 84) was observed for ADG (P less than .05 and P less than .07, respectively), feed conversion (P less than .05 and P less than .07, respectively), and protein deposition (for d 0 to 29 and d 0 to 84; P less than .07 and P less than .05, respectively). These interactions were attributed to a greater response to I by Angus than by Brangus steers. A feeding x period interaction (P less than .10) was observed for mean GH concentration, and INS, T4, and T3 concentrations were higher (P less than .05) during the 4-h postfeeding period than during the 4-h prefeeding period. The implant increased (P less than .08) mean GH concentration but did not alter the frequency, duration, or amplitude of plasma GH peaks. Steers that were implanted had lower (P less than .05) plasma T3. Brangus steers had lower (P less than .05) plasma glucose, T3, and T4 concentrations than Angus steers. Results indicate that growth factors beyond those measured are responsible for the anabolic response to zeranol.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2527/1991.6941688x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!