A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative analysis of clinical dynamic contrast-enhanced MR imaging for evaluating treatment response in human breast cancer. | LitMetric

Purpose: To develop a method that combines a fixed-T1, fuzzy c-means (FCM) technique with a reference region (RR) model (T1-FCM method) to estimate pharmacokinetic parameters without measuring the arterial input function or baseline T1, or T1(0), and to demonstrate its feasibility in the assessment of treatment response to neoadjuvant chemotherapy (NAC) in patients with breast cancer by using data from dynamic contrast material-enhanced magnetic resonance (MR) imaging.

Materials And Methods: This study was approved by the human investigation committees of the two participating institutions. All patients gave written informed consent. A conventional dual-flip-angle gradient-echo method was used to evaluate the effects of noise and the T1 in the tissue itself on the accuracy of T1 estimation. Both conventional RR and fixed-T1 methods were used to evaluate the effects of noise and preselected T1(0) on the estimation of pharmacokinetic parameters by means of a simulation study. Thirty-three women (age range, 32-66 years; mean age, 45 years) with pathologically proved breast tumors were examined to evaluate the feasibility of using the T1-FCM method as a means of assessing treatment response to NAC. A nonparametric Mann-Whitney U test was used to assess the difference in each of the MR imaging parameters between patients with a major histologic response to treatment and those with a nonmajor histologic response.

Results: With use of the dual-flip-angle method, the accuracy and distribution of T1 estimation are dependent on the T1 in the tissue itself. The T1-FCM method is more accurate than other methods and is relatively insensitive to the effects of noise and incorrect T1(0) selection. Preliminary clinical data revealed a significant difference (P < .01) in the change of the volume transfer constant after two cycles of NAC between the major and nonmajor histologic response groups.

Conclusion: Results of the simulation study demonstrate that the T1-FCM method appears to be relatively insensitive to noisy dynamic contrast-enhanced MR imaging data. This method could prove useful in the evaluation of breast cancer therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2941722PMC
http://dx.doi.org/10.1148/radiol.10092169DOI Listing

Publication Analysis

Top Keywords

t1-fcm method
16
treatment response
12
breast cancer
12
effects noise
12
dynamic contrast-enhanced
8
contrast-enhanced imaging
8
method
8
pharmacokinetic parameters
8
evaluate effects
8
simulation study
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!