The development of a screen-printed strip-based amperometric biosensor for the determination of myeloperoxidase (MPO) levels is reported. The biosensor utilizes 3,3',5,5'-tetramethylbenzidine (TMB) as a redox mediator to enable high-sensitivity quantification of physiological levels of MPO. A multivariate parameter optimization was performed. Under the optimal conditions, physiological levels of MPO between 3 and 18 U/L were detected in both acetate buffer (pH 4.5) and human serum using flexible screen-printed electrodes (SPE). The potential interference generated by common serum-based electroactive compounds and a similar peroxidase enzyme was also investigated. The proposed detection methodology offers a simpler, more rapid, and cost-effective alternative to conventional MPO immunoassays, thereby leading to further development in point-of-care testing of acute cardiac events.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2010.07.031DOI Listing

Publication Analysis

Top Keywords

strip-based amperometric
8
physiological levels
8
levels mpo
8
amperometric detection
4
detection myeloperoxidase
4
myeloperoxidase development
4
development screen-printed
4
screen-printed strip-based
4
amperometric biosensor
4
biosensor determination
4

Similar Publications

An electrochemical-sensor system for real-time flow measurements in porous materials.

Biosens Bioelectron

August 2015

Department of Biomedical Engineering, School of Life Sciences, Ulsan National, Institute of Science and Technology (UNIST), 100 Banyeon-ri, Eonyang-eup, Ulju-gun, Ulsan 689-798, Republic of Korea; Center for Soft and Living Matter, Institute for Basic Science (IBS), UNIST-gil 50, Ulsan 689-798, Republic of Korea. Electronic address:

Flow monitoring in porous materials is critical for the engineering of paper-based microfluidic bioassays. Here, we present an electrochemical-sensor system that monitors the liquid flow in porous materials without affecting the real flow in paper-strip samples. The developed microfluidic sensor records an amperometric signal created by the solution movement mediated by paper wicking.

View Article and Find Full Text PDF

The development of a screen-printed strip-based amperometric biosensor for the determination of myeloperoxidase (MPO) levels is reported. The biosensor utilizes 3,3',5,5'-tetramethylbenzidine (TMB) as a redox mediator to enable high-sensitivity quantification of physiological levels of MPO. A multivariate parameter optimization was performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!