Drop shape techniques are widely used for surface tension measurement. As the shape becomes close to spherical, the performance of drop shape techniques deteriorates. A quantitative criterion called shape parameter was previously introduced to quantify the meaning of "well-deformed" drops and "close to spherical" drops. In this paper, a modified definition of the shape parameter that does not depend on the radius of curvature at the drop apex is proposed. Such definition is applicable to different constellations of pendant and sessile drops/bubbles. Dimensional analysis is used to describe similarity in constrained sessile drop shapes and to express the problem using appropriate dimensionless groups. The proposed shape parameter is found to depend only on two dimensionless groups: the dimensionless volume (drop volume normalized by the cube of the holder radius) and the Bond number (using the drop holder's radius as the length scale). A critical shape parameter (minimum value of the shape parameter that guarantees a specified accuracy) is shown to depend only on Bond number. A set of experiments were performed with pure liquids to illustrate the change of the critical shape parameter with the Bond number.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/la1020675 | DOI Listing |
Sci Rep
January 2025
Department of Endodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
The preservation of the original configurations of root canals during endodontic preparation is crucial for treatment success. Nickel-titanium (NiTi) rotary systems have been refined to optimize canal shaping while minimizing iatrogenic errors. This study aimed to evaluate and compare the shaping efficacy of the novel R-Motion (RM) and the established WaveOne Gold (WG) systems using micro-computed tomography (micro-CT).
View Article and Find Full Text PDFSci Rep
January 2025
Civil and Environmental Engineering Department, Faculty of Engineering Sciences, Ben- Gurion University of the Negev, Beer-Sheva, Israel.
The concept of friction was integrated into the broader field of tribology in the 20th century. Here, we revive the older friction coefficient concept and show that it is the defining parameter for a family of granular materials. We show, for the first time, that kinetic friction coefficients of such systems can be described as a function of the lubricating fluid and the shape of the granules, without any fitting parameters.
View Article and Find Full Text PDFJ Comput Chem
January 2025
Universidade de São Paulo, Instituto de Química, Departamento de Química Fundamental, São Paulo, Brazil.
Seventeen electronic states of the dication VH were characterized by the SA-CASSCF/icMRCI methodology using very extended basis sets; 11 were described for the first time. Potential energy curves were constructed and the associated spectroscopic parameters evaluated. Triplet and quintet states correlating with the V + H channel are thermodynamic stable.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Medical Pathology, Ege University Faculty of Medicine, Ege University Hospital, Bornova, İzmir, Turkey.
This study aimed to evaluate the diagnostic accuracy of ultrasonography in assessing the response of clipped axillary lymph nodes to neoadjuvant chemotherapy. Between February 2022 and September 2023, 43 patients who underwent axillary lymph node marking for targeted axillary dissection were retrospectively analyzed. Ultrasonography parameters such as the number, size, shape, cortical thickness, hilum status, and treatment response of the clipped lymph node were assessed.
View Article and Find Full Text PDFUltrasound Med Biol
January 2025
Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China. Electronic address:
Objective: To evaluate the added value of dynamic contrast-enhanced ultrasound (DCE-US) analysis in pre-operative differential diagnosis of small (≤20 mm) solid pancreatic lesions (SPLs).
Methods: In this retrospective study, patients with biopsy or surgerical resection and histopathologically confirmed small (≤20 mm) SPLs were included. One wk before biopsy/surgery, pre-operative B-mode ultrasound and contrast-enhanced ultrasound were performed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!