A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Control of sevoflurane anesthetic agent via neural network using electroencephalogram signals during anesthesia. | LitMetric

In this study, power spectrum of the EEG data and the heartbeat data obtained from 250 patients has been applied to the designed Neural network system. A backpropagation artificial neural network has been developed which contains 53 nodes in the input layer, 27 nodes in the hidden and 1 node in the output layer. In the artificial neural network inputs, the power spectral density values corresponding 1-50 Hz frequency interval of the EEG slices which has 10 seconds of time interval, the ratio of the total of the PSD values of current EEG slice to the total PSD values of EEG slice of pre-anesthesia, the ratio of the total PSD values of the EEG data to the total PSD values of the previous EEG data, and the previous anaesthetic gas ratio values have been applied and the network has been educated. The designed neural network system has been tested by using 10 data set obtained from 4 different patients. In the anesthetic gas prediction according to the anesthesia level, successful results have been obtained with the designed system. The system has been able to correctly purposeful responses in average accuracy of 94% of the cases. This method is also computationally fast and acceptable real-time clinical performance has been obtained.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10916-010-9489-9DOI Listing

Publication Analysis

Top Keywords

neural network
20
total psd
16
psd values
16
eeg data
12
designed neural
8
network system
8
artificial neural
8
ratio total
8
eeg slice
8
values eeg
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!