A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Effect of magnetic fields from home-use magnetic induction therapy apparatuses on adjustable cerebrospinal fluid shunt valves]. | LitMetric

Objective: Cerebrospinal fluid (CSF) shunts are frequently used to treat hydrocephalus. The use of a programmable valve allows the operator to easily change the opening pressure. In Japan, many people use magnetic induction therapy apparatuses in their homes. However, exposing patients with adjustable CSF shunt valves to the permanent magnets included in these apparatuses may alter the shunt valve's programmed settings or permanently damage the device. Therefore, the goal of this study was to determine the health risk associated with magnetic induction therapy for patients using programmable CSF shunt valves.

Methods: Five models of shunt valves from five different manufacturers, the Miethke proGAV (proGAV), the Codman Hakim programmable valve (CHPV), Sophysa Sophy model SM8 (Sophy valve), Sophysa Polaris model SPV (Polaris valve), and Strata II valve (Strata valve) were evaluated in this study. Magnetic field interactions were determined for the programmable valves by using magnetic stones with various magnetic flux densities. The maximum distance between the valve and the magnetic stone affecting the valve pressure setting was measured by X-ray.

Results: The proGAV and Polaris valve were immune to unintentional reprogramming by the magnetic stones. The CHPV, Sophy valve and Strata valve, however, randomly changed settings by magnetic stones.

Conclusions: Whereas the CHPV, Sophy valve and Strata valve were promptly reset by exposure to a magnetic stone with a similar strength to that used in magnetic induction therapy, proGAV and Polaris valve were resistant to inadvertent reprogramming when exposed to magnets up to 190 mT.

Download full-text PDF

Source

Publication Analysis

Top Keywords

magnetic induction
16
induction therapy
16
valve strata
16
strata valve
16
valve
14
sophy valve
12
polaris valve
12
magnetic
11
therapy apparatuses
8
cerebrospinal fluid
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!