A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prevalence of fracture and fragment embolization of Bard retrievable vena cava filters and clinical implications including cardiac perforation and tamponade. | LitMetric

Background: Vena cava filters represent an alternative treatment option for patients with contraindications to anticoagulation, or they might serve as adjunctive treatment for continued emboli despite anticoagulation. The fracture of a filter strut with subsequent end-organ embolization is a rarely reported but potentially life-threatening occurrence.

Methods: We sought to determine the prevalence of fracture and embolization of the Bard Recovery (first generation) and the Bard G2 (second generation) vena cava filters. A retrospective, single-center, cross-sectional study was conducted by evaluating all patients who received either a Bard Recovery or Bard G2 filter from April 2004 until January 2009. A total of 189 patients had undergone implantation: 1 pregnant woman and 35 patients who died were excluded from our study. In addition, 10 patients who had the filter removed were also excluded. Ultimately, 80 patients participated in the trial. Subjects underwent fluoroscopy to assess the filter's integrity. Embolized struts were localized by fluoroscopy. Echocardiography and cardiac computed tomography were performed in patients with fragment embolization to the heart.

Results: Thirteen of 80 patients had at least 1 strut fracture (16%). At least 1 strut in 7 of the 28 Bard Recovery filters fractured and embolized (25%). In 5 of these 7 cases, patients had at least 1 fragment embolize to the heart (71%). Three patients experienced life-threatening symptoms of ventricular tachycardia and/or tamponade, including 1 patient who experienced sudden death at home. Six of 52 Bard G2 filters fractured (12%). In 2 of these 6 cases, the patients had asymptomatic end-organ fragment embolization.

Conclusion: The Bard Recovery and Bard G2 filters had high prevalences of fracture and embolization, with potentially life-threatening sequelae.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archinternmed.2010.316DOI Listing

Publication Analysis

Top Keywords

bard recovery
16
vena cava
12
cava filters
12
patients
11
bard
9
prevalence fracture
8
fragment embolization
8
embolization bard
8
fracture embolization
8
recovery bard
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!