The ability to isolate interstitial fluid (IF) from skin would make it possible to study the microcirculation and proteins in this environment both during normal and pathophysiological conditions. Traditional IF sampling using implanted wicks suffer from low volumes with risk of contamination by local inflammatory, intracellular, and vascular proteins. To sample larger volumes of true IF, a recently described tissue centrifugation method was compared with dry and wet wicks from porcine skin under normal conditions and following volume expansion. With all three methods, volume expansion caused a significant lowering of interstitial colloid osmotic pressure as expected, and the fluid was similar to plasma when compared using size-exclusion HPLC. The centrifugation method was superior with respect to isolating larger amounts of true IF for further studies. Mass spectrometry of IF sampled with centrifugation showed that most of the proteins reflected the major plasma proteins with some tissue-specific proteins like decorin, gelsolin, and orosomucoid-1. Lumican, pigment epithelium-derived factor, and fatty acid-binding protein 4 were only identified in IF after volume expansion, possibly reflecting a local response to increased fluid filtration. Tissue centrifugation to collect IF from skin should be applicable to both clinical and experimental studies on IF balance during different pathophysiological conditions and interventions.

Download full-text PDF

Source
http://dx.doi.org/10.1152/ajpheart.01142.2009DOI Listing

Publication Analysis

Top Keywords

volume expansion
16
interstitial fluid
8
fluid skin
8
pathophysiological conditions
8
tissue centrifugation
8
centrifugation method
8
proteins
5
isolation interstitial
4
fluid
4
skin
4

Similar Publications

Sn-based electrodes are promising candidates for next-generation lithium-ion batteries. However, it suffers from deleterious micro-structural deformation as it undergoes drastic volume changes upon lithium insertion and extraction. Progress in designing these materials is limited to complex structures.

View Article and Find Full Text PDF

Low-Impedance Hybrid Carbon Structures on SiO: A Sequential Gas-Phase Coating Approach.

Small Methods

January 2025

BCMaterials, Basque Centre for Materials, Applications and Nanostructures; UPV/EHU Science Park, Leioa, 48940, Spain.

Carbon coating on SiO surface is crucial for enhancing initial Coulombic efficiency (ICE) and cycling performance in batteries, while also buffering volume expansion. Despite its market prevalence, the effects of the carbon layer's quality and structure on the electrochemical properties of SiO remain underexplored. This study compares carbon layers produced via gas-phase and solid-phase coating methods, introducing an innovative technique that sequentially uses two gases to develop a low-impedance hybrid carbon structure.

View Article and Find Full Text PDF

Silicon is widely recognized as a promising anode material for all-solid-state batteries (ASSBs) due to exceptional specific capacity, abundant availability, and environmental sustainability. However, the considerable volume expansion and particle fragmentation of Si during cycling lead to significant performance degradation, limiting its practical application. Herein, the development of a pre-lithiated Si-based composite anode (c-LiSi) is presented, designed to address the key challenges faced by Si-based anodes, namely severe volume changes and low electrochemical stability.

View Article and Find Full Text PDF

Objectives: The current study was conducted to assess the volume of the tongue, oral cavity, and tongue/oral cavity and their correlation with the volume of the upper airway in cleft subjects compared with the control group.

Methods: The study population included 60 CBCT images from dental school. The sample comprised 30 unilateral cleft patients and 30 sex and age-matched healthy subjects.

View Article and Find Full Text PDF

Damage due to ice crystallization.

Sci Rep

January 2025

Van der Waals-Zeeman institute, Institute of Physics, University of Amsterdam, Science Park 904, 1098 XH, Amsterdam, The Netherlands.

The freezing of water is one of the major causes of mechanical damage in materials during wintertime; surprisingly this happens even in situations where water only partially saturates the material so that the ice has room to grow. Here we perform freezing experiments in cylindrical glass vials of various sizes and wettability properties, using a dye that exclusively colors the liquid phase; this allows precise observation of the freezing front. The visualization reveals that damage occurs in partially water-saturated media when a closed liquid inclusion forms within the ice due to the freezing of the air/water meniscus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!