A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Subcutaneous glucose monitoring with GlucoDay: comparison of the results to those obtained with the endocrine artificial pancreas. | LitMetric

Objective: This study was undertaken to assess the accuracy of GlucoDay- a portable detector of subcutaneous glucose--by comparing the results to those obtained by Biostator an established and reliable method for continuous glucose measurement in whole blood.

Design: Subjects with type 1 diabetes (n:6), subjects with type 2 diabetes (n:6), and six healthy controls were studied for 24 hours; they consumed three main meals. The GlucoDay was connected to the subjects by inserting a microfibre probe into the periumbilical subcutaneous area, whilst the Biostator was inserted by a double-lumen catheter into an antecubital vein. A third catheter was inserted into a separate vein for blood withdrawal to measure glucose by the hexokinase method.

Results: The three methods (GlucoDay-Biostator-hexokinase) were equally accurate in measuring glucose levels (p = 0.233, Kruskall-Wallis test). The glucose measurements performed with GlucoDay and Biostator were significantly correlated with those performed with hexokinase (p < 0.001, r2 = 66.65% and p < 0.001, r2 = 64.4%, respectively, using simple regression analysis).

Conclusions: Measurements of glucose fluctuations in the subcutaneous tissue with the GlucoDay were close to those in blood determined by the Biostator. GlucoDay is therefore a reliable method for continuous glucose monitoring and may prove useful for optimizating treatment in patients with type 1 or type 2 diabetes.

Download full-text PDF

Source
http://dx.doi.org/10.14310/horm.2002.1264DOI Listing

Publication Analysis

Top Keywords

type diabetes
12
glucose monitoring
8
reliable method
8
method continuous
8
continuous glucose
8
subjects type
8
glucose
6
glucoday
5
subcutaneous
4
subcutaneous glucose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!