In elastography, displacement estimation is often performed using cross-correlation-based techniques, assuming fully-developed, homogeneous speckle. In the presence of a local, large variation in echo amplitude, such as a reflection from a vessel wall, this assumption does not hold true, resulting in a biased displacement estimate. Normalizing the echo by its envelope before displacement estimation reduces this effect at the cost of larger jitter errors. An algorithm is proposed to reduce amplitude-dependent bias in displacement estimates while avoiding a large increase in the jitter error magnitude. The algorithm involves 'Envelope-Weighted Normalization' (EWN) of echo data before displacement estimation. A parametric analysis was conducted to find the optimum parameters with which this technique could be implemented. The EWN technique was found to significantly reduce the rms error of the displacement estimates, showing the greatest improvements when utilizing longer window lengths and higher ultrasonic frequencies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4409699 | PMC |
http://dx.doi.org/10.1177/016173461003200201 | DOI Listing |
Curr Pain Headache Rep
January 2025
Universidad de Alcalá, School of Medicine and Health Sciences, Department of Surgery, Medical and Social Sciences, Area of Human Anatomy and Embryology, Universidad de Alcalá, University Campus - C/ 19 Av de Madrid Km 33 600, 28871, Alcalá de Henares, Madrid, Spain.
Purpose Of Review: Low back pain (LBP) is considered an important issue of public health, with annual prevalence estimations almost achieving 60% of the worldwide population. Available treatments have a limited impact on this condition, although they allow to alleviate pain and recover the patient's quality of life. This review aims to go deeper on the understanding of this condition, providing an updated, brief, and concise whole picture of this common musculoskeletal problem.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Institute of Human Movement Science, Sport and Health, University of Graz, 8010 Graz, Austria.
Unlabelled: In recent years, the EnodePro device has been one of the most frequently used velocity sensors to track the bar velocity in resistance training, with the aim of providing load-velocity profiles. However, recent articles highlight a lack of reliability and validity in the estimated maximal strength, which can cause a serious health risk due to the overestimation of the bar velocity. With this study, we aimed to investigate whether imprecision in the measurement could explain the variance in this measurement error.
View Article and Find Full Text PDFBrain Lang
January 2025
Department of Veterans Affairs Rehabilitation Research and Development Brain Rehabilitation Research Center at the Malcom Randall VA Medical Center, Gainesville, FL 32608, USA; University of Florida Department of Neurology, Gainesville, FL 32610, USA; Neurology Service, North Florida/South GeorgiaUSA Veterans Health System and Department of Neurology, University of Florida, Gainesville, FL 32608, USA. Electronic address:
Introduction: Although many white matter tracts underlying language functions have been identified, even in aggregate they do not provide a sufficiently detailed and expansive picture to enable us to fully understand the computational processes that might underly language production and comprehension. We employed diffusion tensor tractography (DTT) with a tensor distribution model to more extensively explore the white matter tracts supporting core language functions. Our study was guided by hypotheses stemming largely from the aphasia literature.
View Article and Find Full Text PDFJ Bone Joint Surg Am
October 2024
Department of Orthopaedics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada.
Background: Fixation of distal femoral fractures remains a challenge, and nonunions are common with standard constructs. Far cortical locking (FCL) constructs have been purported to lead to improved fracture-healing as compared with that achieved with traditional locking bridge plates. We sought to test this hypothesis in a comparative effectiveness clinical trial.
View Article and Find Full Text PDFCureus
December 2024
Department of Orthopedic Surgery, Japanese Red Cross Shizuoka Hospital, Shizuoka, JPN.
Total hip arthroplasty (THA) is a highly effective surgical intervention for end-stage hip joint disorders. While common complications such as infection, dislocation, and prosthetic loosening are well-documented, rarer complications remain underreported. One such complication is foreign body interposition on the bearing surface, which can compromise joint mechanics and adversely affect outcomes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!