We investigated the effect of amplitude-modulated (AM) ultrasound (US) on acousto-optic (AO) signals. A phantom was exposed to both AM US and a green laser, and CCD measurements of speckle contrast were made with various exposure times. The results show that the AO signal oscillates at the AM frequency when the CCD exposure time is a fraction of the AM period and stops oscillating when the CCD exposure time is a multiple of the AM period. The AO signal decreases quickly as the AM frequency increases or peak-peak (pk-pk) amplitude decreases. With 4ms exposure time, 250Hz AM frequency and 1.27MPa pk-pk acoustic pressure, there is an ~30% increase in the AO signal compared with that of CW US. The increase in the signal is likely to be due to the particle oscillation and the induced shear wave as a result of the radiation force generated by the AM US.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.35.002633 | DOI Listing |
JAMA Netw Open
January 2025
Johns Hopkins Ciccarone Center for the Prevention of Cardiovascular Disease, Johns Hopkins University School of Medicine, Baltimore, Maryland.
Importance: Obesity, a chronic disease with escalating global prevalence, poses considerable health risks. Glucagon-like peptide 1 receptor agonists (GLP-1RAs), including liraglutide, semaglutide, and tirzepatide, have demonstrated efficacy for weight loss in clinical trials. The paradigm shift in the approach to obesity management drugs (OMDs) may offer an opportunity to examine online search activity and prescription trends.
View Article and Find Full Text PDFDrug Deliv Transl Res
January 2025
Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi, 110062, India.
The global prevalence of Parkinson's Disease (PD) is on the rise, driven by an ageing population and ongoing environmental conditions. To gain a better understanding of PD pathogenesis, it is essential to consider its relationship with the ageing process, as ageing stands out as the most significant risk factor for this neurodegenerative condition. PD risk factors encompass genetic predisposition, exposure to environmental toxins, and lifestyle influences, collectively increasing the chance of PD development.
View Article and Find Full Text PDFDrug Deliv Transl Res
January 2025
Kinimmune, Inc. St. Louis, 63141, Missouri, USA.
PD-L1/PD-1 checkpoint inhibitors (CPIs) are mainstream agents for cancer immunotherapy, but the prognosis is unsatisfactory in solid tumor patients lacking preexisting T-cell reactivity. Adjunct therapy strategies including the intratumoral administration of immunostimulants aim to address this limitation. CpG oligodeoxynucleotides (ODNs), TLR9 agonists that can potentiate adaptive immunity, have been widely investigated to tackle PD-L1/PD-1 resistance, but clinical success has been hindered by inconsistent efficacy and immune-related toxicities caused by systemic exposure.
View Article and Find Full Text PDFNaunyn Schmiedebergs Arch Pharmacol
January 2025
Center of Studies and Research Toxic-Pharmacological, School of Pharmacy, Federal University of Goias, Leste Universitario, 240th Street, Corner of 5th Avenue, Goiania, GO, 74605-170, Brazil.
The CCl-induced hepatotoxicity model is a traditional preclinical assay applied to evaluate potential hepatoprotective compounds. However, several studies have used it with inappropriate dose and exposure time, generating both weak response or irreversible liver injury, as well as lack of representative liver and plasma biomarkers. Therefore, this study aims to determine the best dose and exposure time of CCl in Wistar rats, permitting a proper evaluation of potential hepatoprotective effect.
View Article and Find Full Text PDFR I Med J (2013)
February 2025
Alpert Medical School of Brown University, Department of Medicine, Division of Cardiology, Rhode Island Hospital.
Cardiac Positron Emission Tomography (PET) can be used for the assessment of myocardial perfusion. Compared to other cardiac imaging techniques, notably Single Photon Emission Computer Tomography (SPECT), cardiac PET offers superior image resolution, higher accuracy, quantitative measures of myocardial perfusion, lower radiation exposure, and shorter image acquisition time. However, PET tends to be costlier and less widely available than SPECT due to the specialized equipment needed for generating the necessary radiotracers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!