A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of plain balloon and cutting balloon angioplasty for the treatment of restenosis with drug-eluting stents vs bare metal stents. | LitMetric

Background: The efficacy of cutting or plain balloon angioplasty (CBA or PBA) has not been analyzed for the treatment of drug-eluting stent (DES) restenosis vs bare metal stent (BMS) restenosis.

Methods And Results: The 252 in-stent restenosis (ISR) lesions in 224 consecutive patients treated by CBA (n=167) or PBA (n=85) between July 2002 and December 2007 were analyzed. At 6-month angiographic and 12-month clinical follow-up, CBA and PBA showed similar efficacies: repeat-ISR (37.0% vs 37.8%, P=0.90), late loss (0.62+/-0.60 vs 0.61+/-0.47 mm, P=0.92), and target lesion revascularization (18.3% vs 22.4%, P=0.50). This comparable efficacy was maintained for treatment in the DES-ISR and BMS-ISR subgroups. However, target lesion-related myocardial infarction (n=9) occurred more frequently in the CBA than in the PBA arm (6.2% vs 0%, P=0.03), most of which developed early after ISR treatment (n=7; 54+/-26 days). Independent predictors of repeat-ISR were diffuse ISR and smaller pretreatment minimal lumen diameter, both of which might imply heavier plaque burden in the ISR group.

Conclusions: Plain or cutting balloon angioplasty for ISR seems to be comparable, as the angiographic or clinical endpoints were not affected by initial stent type but by parameters related to the plaque burden of the ISR lesion. However, CBA might be associated with higher risk of myocardial infarction than PBA, suggesting more attention to dual-antiplatelet therapy after its use for ISR.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.cj-09-1041DOI Listing

Publication Analysis

Top Keywords

balloon angioplasty
12
cba pba
12
plain balloon
8
cutting balloon
8
bare metal
8
myocardial infarction
8
plaque burden
8
burden isr
8
isr
7
cba
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!