Objectives: We evaluated the efficiency and safety of the Occlutech Figulla device in percutaneous closure of secundum atrial septal defects (ASD).
Study Design: The study included 28 patients (17 women, 11 men; mean age 43 years) who underwent percutaneous transcatheter closure using the Occlutech Figulla device for secundum ASDs causing a hemodynamically significant shunt. Defect size was estimated by transthoracic (TTE) and transesophageal (TEE) echocardiography, and also by balloon sizing in nine patients. The patients were followed-up for six months and were examined by TTE.
Results: The mean defect size was 20.3+/-2.1 mm on TTE, 22.1+/-1.9 mm on TEE, and 24.2+/-2.4 mm on balloon sizing. The mean device size was 26.8+/-3.6 mm (range 6 to 36 mm). The mean procedure time was 44.7+/-21.4 minutes. The device was placed successfully in all the patients. A small residual flow was seen immediately after device placement in three patients (10.7%), which disappeared in two patients at three months, and in one patient at six months. During the procedure, complications were seen in four patients (14.3%), including transient sinus tachycardia in three patients (10.7%) and acute atrial fibrillation in one patient (3.6%). At six months, all the patients were asymptomatic. No ischemic stroke, cardiac perforation, device erosion, embolization, thrombus formation, or malposition of the device were observed.
Conclusion: The Occlutech Figulla occluder is a safe and efficient device to close secundum ASDs. It may be preferred especially in patients with a high risk for thrombus formation.
Download full-text PDF |
Source |
---|
Ann Pediatr Cardiol
May 2024
Department of Pediatrics and Adolescent Medicine, Children's Heart Center, American University of Beirut Medical Center Beirut, Lebanon.
We describe a unique report of percutaneous closure of multiple secundum atrial septal defects in a child utilizing three Occlutech Figulla septal occluders deployed sequentially. The procedure was performed under live three-dimensional transesophageal echocardiography guidance.
View Article and Find Full Text PDFJ Clin Med
March 2024
Royal Brompton & Harefield NHS Foundation Trust, Sydney Street, London SW3 6NP, UK.
Transcatheter closure of a patent foramen ovale (PFO) is performed in cryptogenic stroke and other conditions. Information is lacking for some devices. We aimed to evaluate the Figulla Flex II PFO Occluder (FFP) and Figulla Flex UNI Occluder (FFU) through a retrospective multi-center registry.
View Article and Find Full Text PDFJ Invasive Cardiol
April 2024
The Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland. Email:
Objectives: Percutaneous closure of a patent foramen ovale (PFO) for the prevention of recurrent paradoxical thromboembolic events has been shown to be safe and effective in randomized controlled trials. However, it remains uncertain if differences in the structure and design of the occluder devices impact the outcomes. The aim of this study was to compare results of percutaneous PFO closure using 2 widely used double-disc occluders.
View Article and Find Full Text PDFJ Clin Med
September 2023
University Cardiology Department, Galeazzi-Sant'Ambrogio Hospital, Scientific Institute for Research, Hospitalization and Healthcare (I.R.C.C.S.), Via Cristina Belgioioso 173, 20157 Milan, Italy.
Introduction: The aim of this study was to assess clinical outcomes and quality of life after PFO closure in patients with previous stroke/TIA of undetermined cause and in patients with other complex PFO-associated clinical conditions.
Methods: Between July 2009 and December 2019 at our University Cardiology Department, 118 consecutive patients underwent a thorough diagnostic work-up including standardized history taking, clinical evaluation, full neurological examination, screening for thrombophilia, brain magnetic resonance imaging (MRI), ultrasound-Doppler sonography of supra-aortic vessels and 24 h ECG Holter monitoring. Anatomo-morphological evaluation using 2D transthoracic/transesophageal echocardiography (TTE/TEE) color Doppler and functional assessment using contrast TTE (cTTE) in the apical four-chamber view and contrast transcranial Doppler (cTCD) using power M-mode modality were performed to verify the presence, location and amount of right-to-left shunting via PFO or other extracardiac source.
Cardiovasc Revasc Med
December 2023
Friedrich-Schiller University, Jena, 07743 Jena, Germany. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!