X-ray photoelectron spectroscopy (XPS) was used to identify Mn(II), Mn(III), and Mn(IV) in the surfaces of pure oxide standards and filtration media samples from drinking water treatment plants through the determination of the magnitude of the Mn 3s multiplet splitting and the position and shape of the Mn 3p photo-line. The Mn 3p region has been widely studied by applied physicists and surface scientists, but its application to identify the oxidation state of Mn in heterogeneous oxide samples has been limited. This study shows that the use of both the Mn 3s multiplet splitting and the position and shape of the Mn 3p photo-line provides a feasible means of determining the oxidation state of manganese in complex heterogeneous, environmentally important samples. Surface analysis of filtration media samples from several drinking water treatment plants was conducted. While Mn(IV) was predominant in most samples, a mixture of Mn(III) and Mn(IV) was also identified in some of the filtration media samples studied. The predominance of Mn(IV) in the media samples was felt to be related to the maintenance of free chlorine (HOCl) at substantial concentrations (2-5 mg*L(-1) as Cl2) across these filters. XPS could be a useful tool to further understand the specific mechanisms affecting soluble Mn removal using MnOx-coated filtration media.

Download full-text PDF

Source
http://dx.doi.org/10.1021/es100547qDOI Listing

Publication Analysis

Top Keywords

filtration media
20
media samples
16
oxidation state
12
samples drinking
12
drinking water
12
water treatment
12
treatment plants
12
xps identify
8
identify oxidation
8
samples
8

Similar Publications

This study investigated the adsorptive properties of functionalized fabric containing dimethylaminomethyl calix[4]arene (DMAM-Calix) to remove anionic methyl orange (MO) and cationic Rhodamine B (RhB) dyes in aqueous media. Adsorption studies were performed using a filtration system packed with DMAM-Calix-functionalized fabric (). The results revealed that the cationic and anionic structures work compatibly in a binary mixture medium.

View Article and Find Full Text PDF

Comparison of Influence of Office and 24-h Central Aortic Blood Pressure on Target Organ Damage in Hypertension.

J Clin Hypertens (Greenwich)

January 2025

Department of Geriatrics, Medical Center on Aging of Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.

The aim of this study was to explore whether 24-h ambulatory central (aortic) blood pressure (BP) has an advantage over office central aortic BP in screening for hypertension-mediated target organ damage (HMOD). A total of 714 inpatients with primary hypertension and the presence of several cardiovascular risk factors or complications involving clinical HMOD were enrolled. Twenty-four hour central aortic BP was measured by means of a noninvasive automated oscillometric device (Mobil-O-Graph).

View Article and Find Full Text PDF

Deteriorated abatement of micropollutants in biological activated carbon filters with aged media: Key role of permeability.

Water Res

December 2024

Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China. Electronic address:

Biological activated carbon (BAC) filtration is vital for the abatement of micropollutants in drinking water. However, limited information is available on contaminant removal in BAC filters with aged media (e.g.

View Article and Find Full Text PDF

Advanced micropollutant and phosphorus removal with superfine powdered activated carbon and pile cloth media filtration.

Water Res

December 2024

Department of Civil and Environmental Engineering Sciences, Institute IWAR, Chair of Water and Environmental Biotechnology, Technical University of Darmstadt, Germany. Electronic address:

Organic micropollutants (OMP) are ubiquitous in aquatic ecosystems and have a proven negative impact on the environment and drinking water resources. To remove OMP from municipal wastewater, the use of superfine Powdered Activated Carbon (sPAC) (d = 1.0 µm) compared to Powdered Activated Carbon (PAC) (d = 30.

View Article and Find Full Text PDF

Evaluation of glomerular filtration rate estimation through plasma clearance of iohexol in seagulls (Larus michahellis).

BMC Vet Res

January 2025

Department of Veterinary Sciences, Veterinary Teaching Hospital "Mario Modenato", University of Pisa, via Livornese snc, San Piero a Grado, Pisa, Italy.

Background: Current endogenous indicators utilised in avian medicine are not sensitive enough to detect renal disease in its early stages. Alternative markers ought to be examined as a result. The aim is to investigate the accuracy of limited-sampling models for glomerular filtration rate (GFR) in adult seagulls using plasma clearance of iohexol (IOX).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!