A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Microfluidic devices for electrokinetic sample fractionation. | LitMetric

Microfluidic devices for electrokinetic sample fractionation.

Electrophoresis

Department of Chemistry, University of Alberta, Edmonton, AB, Canada.

Published: August 2010

We present three generations of microchip-based "in-space" sample fractionators and collectors for use in proteomics. The basic chip design consisted of a single channel for CE separation of analytes that then intersects a fractionation zone feed into multiple high aspect ratio microchannels for fractionation of separated components. Achievements of each generation are discussed in relation to important design criteria. CE-separated samples were electrokinetically driven to multiple collection channels in sequence without cross-contamination under the protection of sheath streams. A 36-channel fractionator demonstrated the efficacy of a high-throughput fractionator with no observed cross-contamination. A mixture of IgG and BSA was used to test the efficiency of the fractionator and collector. CE of the fractionated samples was performed on the same device to verify their purity. Our demonstration proved to be efficient and reproducible in obtaining non-contaminated samples over 15 sample injections. Experimental results were found to be in close agreement with PSpice simulation in terms of flow behavior, contamination control and device performance. The design presented here has a great potential to be integrated in proteomic platforms.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.201000098DOI Listing

Publication Analysis

Top Keywords

microfluidic devices
4
devices electrokinetic
4
electrokinetic sample
4
sample fractionation
4
fractionation three
4
three generations
4
generations microchip-based
4
microchip-based "in-space"
4
"in-space" sample
4
sample fractionators
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!